26
(2) Auto Start
First, use the voltage regulator dial to adjust the voltage to the specified
value.
Turn on the main breaker on the operation panel of this machine.
Set the accessory switch to "OFF," and use the safety cap to cover it.
Confirm that the fuel spigot is open.
Set the starter switch selector to "AUTO".
The engine starts when the "REMOTE START" terminal closes.
< Note >
Please keep in mind that the muffler may emit some smoke when the engine is started.
Never turn accessory switch ON during operation.The engine keeps running while accessory
Switch is ON
9-2. Procedures during Operation
(1) Checks after Startup
Make sure that all meters and indicators are in normal status. (
Refer to section “5. Equipment”.)
Check that there is no abnormal vibration or noise.
Check that the exhaust gas color is normal. When operation is normal, the exhaust gas should be
colorless or slightly bluish.
< Note >
In the event of abnormalities, stop using this generator and request authorized distributor where
the generator was purchased to repair the generator.
(2) Adjustment during Operation
During load operation, check the voltmeter and finely adjust voltage using the voltage
regulator dial.
Restarting after stopping due to running out of fuel
The fuel filter includes an automatic air-bleeding device. Restart the engine easily according
to the following procedures even if the engine has stopped due to running out of fuel.
Turn the single-phase breakers in the operation panel to OFF position.
Turn the starter switch to STOP.
Add fuel to the fuel tank.
Set the starter switch selector to "START," and confirm that the engine has started
properly.
The engine speed is unstable for approximately one minute until the air has been
completely vented from the fuel line. The engine speed stabilizes once the air is vented.
<
Note >
If the engine stops immediately after starting, the machine tries to restart it automatically.
If the over crank indicator lights up, return the starter switch selector to the "STOP" position first,
and then set it again to "START."
1
2
3
4
5
1
2
3
4
5
6
Содержание DGK7F
Страница 2: ......
Страница 46: ...43 13 Generator Circuit Diagram...
Страница 47: ...44 14 Engine Electrical Circuit Diagram...
Страница 48: ...2018...