19
Single-phase 120V receptacle, single-phase 240/120V receptacle
Allowable output limit as shown below. (kVA)
120V GFCI
120V GFCI
240/120V
Twist
lock
240/120V
Twist
lock
Total
CON1
CON2
CON3
CON4
CON5
CON6
U-W
-
-
6.5
6.5
6.5
U-N
Total 2.4
Total 2.4
3.6
6.0
6.5
W-N
-
-
3.2
3.2
3.2
< Note >
Maximum total allowable capacity is less than 6.5kVA
8. Pre-Operation
CAUTION : BURNS
Do not touch the engine and surrounding components immediately after
stopping the engine as they are still extremely hot.
CAUTION : FIRE
Always be sure to wipe up any spilled fuel or oil.
WARNING : INJURY
Always turn the starter switch to the STOP position and stop the engine, then
close and lock OPERATION PANEL DOOR before checking or maintaining
the engine.
Do not open the inspection door when the starter switch is in the AUTO or
START position. It may get caught in rotating parts such as cooling fans and
fan belt.
Load
240/120V
CON5
U
N
W
120V
120V
240V
Load
240/120V
CON6
240V
120V
W
120V
U
N
Load
120V
CON1
N
U
Load
120V
CON2
N
U
Load
120V
CON3
N
U
Load
120V
CON4
N
U