- 43 -
10.6 Clean gauze filter in water separator
Clean
Every 500 hours
①
①
①
①
Loosen the lever and then loosen the air
extraction plug.
②
②
②
②
Turn the ring nut counter-clockwise
to remove the cup and the gauze filter after the
fuel inside does not come out from the lever.
③
③
③
③
Wash the gauze filter in Diesel fuel and reinstall the unit in the reverse order.
Tightening Torque
Ring Nut
15Nm{1.5kgfm}
Air Extraction Plug
10Nm{1.0kgfm}
<Caution>
Clean the filter more frequently as gauze filter is clogged in shorter period when using the fuel
from the fuel drum than other fuel source.
Put a tray under the lever in order to catch spilled fuel when loosing the lever.
Extract the air in fuel line after gauze filter washing finishes.
(Refer to
9-3. During operation.)
Ensure that there is no fuel leakage after reinstallation.
10.7 Clean gauze filter in engine feed pump
Clean
Every 500 hours
①
①
①
①
Remove eyebolts.
②
②
②
②
Remove gauze filter in eyebolts.
③
③
③
③
Wash gauze filters in Diesel fuel and reinstall
in the reverse order
Eyebolt tightening torque
44Nm{4.5gfm}
AIR
EXTRACTION
PLUG
GAUZE FILTER
RING NUT
EYEBOLT(2)
EYEBOLT(1)
FEED PUMP
JOINTPIPE