Digital Indicator 

SD24 Series 

Instruction Manual

 

 
 

 
 
 

Please be sure to provide the end user with these instructions. 

 

 

Preface 

Thank you for purchasing a Shimaden product. 
After making sure the product you have is the one you specified, get a good understanding of the instructions to ensure proper 
operation and handling. 
This document contains precautions, mounting method, wiring/function descriptions and operation method for those involved 
in wiring, installing and performing routine maintenance for the SD24 Series. 
Keep the instructions in a handy place when operating/handling the SD24 Series and be sure to adhere to the instructions 
contained herein. 
Safety precautions and precautions concerning equipment damage and other additional explanations are provided under the 
following labeling. 

     

WARNING 

Matters that could result in injury or death if instructions are not followed. 

     

Caution 

Matters that could result in equipment damage if instructions are not followed. 

 

 

Note 

Additional explanations or matters requiring special attention. 

 

 

Safety precautions 

 

     

 WARNING 

The SD24 Series digital indicators are designed to indicate temperature, humidity and other physical amounts for general industrial 
equipment. You should either take appropriate safety measures or avoid using for control that could have a serious effect on human life.
The digital indicator should be housed in the control box, etc., to keep the terminal elements from being accidentally touched. 
Do not remove the indicator from its case, or insert your fingers or electric conductors inside the case. Doing so could result in electric 
shock accident involving death or serious injury. 

 

     

 Caution 

If there is danger of damage to any peripheral device or equipment due to failure of the indicator, you should take appropriate safety 
measures such as mounting a fuse or overheating prevention device. 

An alert 

  symbol is printed on the terminal nameplate applied to the case. Alert marks are provided to call your attention to the fact 

that you could be shocked if you touch charged parts. 

Provide a switch or breaker as a means of cutting off power for external power circuit connected to the power terminal of the indicator.
Mount a switch or breaker near the indicator where the operator can get to it easily and label it as an electrical breaker for the indicator.

Содержание SD24 Series

Страница 1: ...al attention Safety precautions WARNING The SD24 Series digital indicators are designed to indicate temperature humidity and other physical amounts for general industrial equipment You should either t...

Страница 2: ...quipment failure or fire Do not allow the draft holes to become clogged with dust etc Doing so could shorten the life of the product due to temperature rise or insulation deterioration and could resul...

Страница 3: ...AL1 AL2 and AL3 AL4 are COM shared Contact capacity 240V AC 2A resistive load 4 Alarm output optional 2 Output 2 points AL1 AL2 contact c Contact capacity 240V AC 2 5A resistive load 00 Without 03 0...

Страница 4: ...ude exceeds 2000 m Note Among environmental conditions IEC60664 installation category II pollution class 2 2 2 Installation 1 Cut a hole for mounting the indicator by referring to the cutout drawing i...

Страница 5: ...agnetic induction noise For power supply use wiring or cable with sectional area of at least 1 mm that offers the same performance as 600V vinyl insulated wiring The ground wire should be at least 2 m...

Страница 6: ...and mode 1 screen group Press and hold for approximately 2 seconds to switch from 0 0 to 1 0 screen group and vice versa Down key Decrements parameter values on the setting screens The decimal point o...

Страница 7: ...eration for mode 0 screen group The mode 0 screen group consists of items that are used frequently during operation The main key operations are as follows Key operation for mode 1 and 2 screen group C...

Страница 8: ...unication protocol 1 26 Communication address 1 27 Communication data 1 28 Start character 1 29 BCC operation 1 30 Communication speed 1 31 Delay time 1 32 1 22 Analog output Scaling higher limit DI1...

Страница 9: ...Linear approximation A2 2 7 Linear approximation B2 2 8 Linear approximation A3 2 9 Linear approximation B3 2 10 Linear approximation A4 2 11 Linear approximation B4 2 12 Linear approximation A5 2 13...

Страница 10: ...7 1 Latching function for alarm output KEEP Latch RSET Unlatch KEEP RSET KEEP 0 3 Alarm 3 unlatching Indicates alarm 3 status Can be unlatched Sets alarm 3 code to type with latching function screen 1...

Страница 11: ...lower limit value with latching function Note Screen is not displayed when alarm 4 code screen 1 17 is non none or in the case of So scale over See 8 Specifications Setting Range Refer to initial valu...

Страница 12: ...dHi_L Deviation higher limit value with latching function dLo_L Deviation lower limit value with latching function dHL_L Deviation higher lower limit value with latching function Note Setting contents...

Страница 13: ...Inverse scaling is possible The same value cannot be set for both higher limit value and lower limit value screen 1 22 Measuring range lower limit value higher limit value Lower limit value 1 22 Analo...

Страница 14: ...EP rAm r_E EEP 5 5 Mode 2 screen group 2 0 Mode 2 initial screen First screen of the mode 2 screen group 2 1 Power frequency Sets displays power frequency Note Does not have to be set under ordinary c...

Страница 15: ...is OFF 5 00 105 00 0 00 2 18 Linear approximation B7 Sets displays linear approximation B7 Note Not displayed when linear approximation screen 2 4 is OFF 5 00 105 00 0 00 2 19 Linear approximation A8...

Страница 16: ...the power is turned off The value when the power is turned back on is then held Note The hold value display is maintained even if the device displays an error message during hold Alarm output is in a...

Страница 17: ...larm 9999 19999 9999 unit dHL Deviation higher lower limit value alarm 1 19999 19999 unit dHi_L Deviation higher limit value alarm with latching function 9999 19999 19999 unit dLo_L Deviation lower li...

Страница 18: ...alarm type is set to HA With standby action the alarm is not output while the power is on even if alarm output conditions are satisfied The alarm is output when the value re enters the alarm range aft...

Страница 19: ...range is 0 0 5 0 of PV input range 7 4 10 segment linear approximation Enabling 10 segment linear approximation Set only for voltage or current input Ineffective during inverse scaling Function that...

Страница 20: ...power supply 24V DC 50 mA and can use it in combination with humidity sensor H71 and TH71 Series For voltage V input connection For current mA input connection 7 8 9 10 TC RTD A B B 7 10 9 22 21 24V D...

Страница 21: ...T N U L DIN43710 WRe5 26 For details see 8 Specifications Measuring Range Codes Lead wire tolerable resistance 100 max Input resistance 500k min Burnout function Standard feature up scale Cold juncti...

Страница 22: ...1 19999 19999 unit Control input DI Number of input points 2 points Type of DI allocation Selected for each DI from among the following 4 types Not assigned HLD Hold Maintains current input value RESE...

Страница 23: ...0 0 0 600 0 0 0 1000 0 0 00 120 00 300 0 900 0 150 0 200 0 150 0 600 0 80 00 100 00 60 00 120 00 40 00 140 00 0 00 180 00 0 00 80 00 0 00 200 00 0 0 400 0 0 0 600 0 0 0 600 0 0 0 900 0 0 00 120 00 0 0...

Страница 24: ...sistance 500V DC 20M min between all input output terminals and power terminals 500V DC 20M min between all input output terminals and ground terminals Dielectric strength 2300V AC between all input o...

Отзывы: