System parameter group 00
PARAMETER DESCRIPTION 82
5.1.1 Inverter information
For checking inverter model, control board firmware version, and the connected expansion card, etc.
Parameter
Name
Default
Setting Range
Content
00-00
P.90
Inverter model
Read only
Read only
---
00-01
P.188
Firmware version
Read only
Read only
Inverter control board firmware version
Inverter model
00-00
(P.90)
=
Input voltage: 1: 220V 1-PHASE
2: 220V 3-PHASE
3: 440V 3-PHASE
Applicable motor capacity:
please refer to the following table
Applicable motor capacity:
Value(value of the two low-order bits
of 00-00(P.90))
Capacity (kw)
Value (value of the two low-order bits
of 00-00(P.90))
Capacity (kw)
3
0.75K/1.5KF
15
45K/55KF
4
1.5K/2.2KF
16
55K/75KF
5
2.2K/3.7KF
17
75K/90KF
6
3.7K/5.5KF
18
90K/110KF
7
5.5K/7.5KF
19
110K/132KF
8
7.5K/11KF
20
132K/160KF
9
11K/15KF
21
160K/185KF
10
15K/18.5KF
22
185K/220KF
11
18.5K/22KF
23
220K/250KF
12
22K/30KF
24
250K/280KF
13
30K/37KF
25
280K/315KF
14
37K/45KF
26
315K/350KF
Note:1.The parameters above are for read only, not for write.
2.Please refer to the user manual section 5.1.15 “Expansion card type” for more details about expansion cards.