Position control parameter 12
PARAMETER DESCRIPTION 282
5.13.1 Homing mode
Set original position of position control with homing function.
Parameter
Name
Default Setting Range
Content
12-00
P.420
Homing mode
0
0~2123
Homing mode setting:
u
x
y
z
u
0
:
Turn off homing mode
1
:
Execute homing mode automatically when
power is on
2
:
Set terminal to SHOM function to initiate homing
mode
x
0
:
After check
,
motor decelerates and returns to
original point.
1
:
Motor stops according to forward direction after
original point check
y
0
:
Return to search for Z phase pulse when in
homing mode
1
:
Search for Z phase pulse in homing mode
without returning
2
:
In homing mode
,
locate searcher or Z phase
pulse
z
0
:
Forward spin return to original point
,
ORGP as
original point
1
:
Reverse spin return to original point
,
ORGP as
original point
2
:
Forward spin search for Z phase directly as
returning point
3
:
Reverse spin search for Z phase directly as
returning point
12-01
P.421
First high speed of
homing
10.00Hz
0~650.00Hz
---
12-02
P.422
Second high speed of
homing
2.00Hz
0~650.00Hz
---
12-03
P.423
Original point deviation
pulse number
0
-30000~30000
---
Homing mode
Homing mode setting table
(
√
represents settable
,×
represents is not settable
)
y
z
0
1
2
3
0
√
√
×
×
1
√
√
×
×
2
√
√
√
√
Setting
Содержание SA3 Series
Страница 2: ......
Страница 420: ...Appendix 6 European Specification Compatibility Description APPENDIX 418 ...
Страница 421: ...Appendix 6 European Specification Compatibility Description Appendix 419 ...