System parameter group 00
PARAMETER DESCRIPTION 98
5.1.15 Expansion card type
This parameter is used to check the expansion card type, and cannot be modified.
Parameter
Name
Default Setting Range
Content
00-26
P.125
Expansion card type
Read
Read only
It is used to display the current expansion card type, for read
only.
Current expansion card type
All bits are 1 when no card insert.
The definition of each 00-26 (P.125) bit is as follows:
bit
2
0
2
8
2
1
2
2
2
3
2
4
2
5
2
6
2
7
2
9
2
10
2
11
SLTO2
SLOT3
bit1
bit0
bit11 bit10
bit9
bit8
bit7
bit6
bit5
bit4
bit3
bit2
SLOT1
The values for all expansion cards are shown in following table:
Expansion card type
Model
Bit value
Communication Expansion card
PD302
0 1 0 1
DN301
1 0 0 1
EC301
1 1 0 0
CP301
1 1 0 1
EP301
0 0 1 1
I/O Expansion card
EB362R
1 0 1 0
EB308R
0 1 1 0
PG Expansion card
PG301C
0 0 0 0
PG301L
0 0 0 1
PG302L
0 0 1 0
For example: Insert CP301 into SLOT1, insert PG302L into SLOT2, and insert EB308R into SLOT3, the read-out value
of 00-26(P.125) is as follows:
bit
2
0
2
8
2
1
2
2
2
3
2
4
2
5
2
6
2
7
2
9
2
10
2
11
0
1
0
1
1
0
0
0
1
0
1
1
So 00-26(P.125) = 0×2
11
+ 1×2
10
+ 1×2
9
+ 0×2
8
+ 0×2
7
+ 0×2
6
+ 1×2
5
+ 0×2
4
+ 1×2
3
+ 0×2
2
+ 0×2
1
+ 0×2
0
= 1581
Note: SLOT1 is only for communication expansion card; SLOT2 is for PG and IO expansion card; SLOT3 is only for IO
expansion card. If the expansion card is loose, the alarm EbE1/EbE2/EbE3 will be activated. Please refer to 7.2
Appendix 2: Alarm code list.