7
1.4 Servo drive appearance and panel description
1.4.1
200V drive appearance and panel
Power indicator
If the indicator is on, it means the
servo drive still has high voltage at
that time.
Control board power supply.
Use single
-
phase( 200-240VAC, 50-60HZ
power supply) to L1, L2 terminal.
Main circuit power supply
Connects R,S,T to commercial
power ( AC200-240V,50-60HZ
power)
Servo motor output
Connects to the motor power connector
U, V, W, Do not connect to the main
circuit power. Incorrect wiring will cause
damage to the servo drive.
Heat sink
For fixing the servo and heat
dissipation.
Display
The 5-digit 7 segment LED
displayer displays the alarm, servo
status, parameter, etc.
Operation panel
To perform function and
parameters setting.
MOD
E
:
Mode selection
5
:
add one on the
displayed value
6
:
deduct one from the
displayed value
SET
:
Press SET button to
confirm the setting
USB connector
Connects the PC and controller.
RS-485 connector
Connects the PC and
controller.
Encoder connector
Connects to the motor encoder
Control interface.
1.controls the external I/O
2. connects to PLC
Grounding terminal
L1
L2
CHARGE
SDP-010A2C
Position feedback
connector
1. Linear scale feedback.
2. Hall sensor connector
STO terminal
Internal /external regenerative
resistor/brake control module.
1. When external regenerative resistor is
used, P and C connect to the resister; P
and D are left open.
2. When internal regenerative resistor is
used, P and C are left open; P and D are
short-circuited (connected)
3. When external regenerative brake unit
is used, P and N connect to the brake
unit; P & C and P & D are left open.
Содержание SDP Series
Страница 33: ...20 400V series DC 24V Power supply Note terminal P N cannot be grounded ...
Страница 42: ...29 2 CN1 connector male Front view Side view Rear view CN1 wiring terminal on the back of CN1 1 26 50 25 ...
Страница 45: ...32 4 The last step is to fasten the screw of housing ...
Страница 203: ...190 It is recommended that the user performs torque position mode switching after motor is stopped completely ...
Страница 385: ...372 ...
Страница 405: ...392 ...
Страница 499: ...486 SME L040 SME L075 SME L100 SME L150 ...
Страница 500: ...487 SME L200 SME L300 SME M100 SME M150 ...
Страница 509: ...496 When the load reaches 300 the operation time is 5 51 seconds ...
Страница 541: ...528 Middle inertia power cable Middle inertia 2KW 3KW 400V High inertia power cable 1 8KW 2 9KW 4 4KW 5 5KW 7 5KW ...