background image

 

24 

 

4. Periodical inspections

 

 

2. Inspection method 

 
To keep the safety of the firefighting pump and make use of every possible function, 
periodical inspections are essential. Inspect the firefighting pump correctly and in 
safe following the procedure below. 
 

     

 

 

 

Start the inspections and services after the engine is stopped and has cooled 
down sufficiently. 

 

If not, injury, burnt, or fire may result. 

 

(1) 

Check and charging of battery 
A) 

Installation and removal of battery. 

 

     

 

 

 

When disconnecting the battery cord, remove the (-) cord first and when 
connecting, connect the (+) cord first. 

 

If not, short circuit may occur and cause a fire or burn you. 

 

B) 

Auxiliary charge   
Battery charging level decreases day by day due to self-discharge even 
if the battery is not used. Consumption by the self-charge, starting motor, 
lamps, etc. should be supplemented by charging. 

 

     

 

 

 

Be sure to use the specified charger. 

 

If not, fire may arise due to overheat, burning of wiring, etc. 

 

     

 

 

 

When the battery cap is removed, do not bring a fire close to the battery. 

 

The electrolyte may catch the fire and explode. 

 
C) 

Replacing timing 
Battery performance is rapidly deteriorated in about 2 years even if the 
battery is correctly handled. It is recommendable to replace the battery 
earlier. 

 
 
 
 
 
 

Caution

 

 

Caution

 

 

Caution

 

 

Caution

 

 

Содержание TF516MH-AB

Страница 1: ...operation manual carefully in order to operate the Shibaura Firefighting Pump in safe and in correct manner If the pump is operated incorrectly any accident may result If this manual is missing or da...

Страница 2: ...3 Handling of pump Before starting operation 9 Operating method 13 Discharging with multiple pumps 19 Suction and discharge of water from Fire hydrant 20 Operation in cold districts in winter 22 4 Per...

Страница 3: ...nger If the machine is operated incorrectly there is high possibility of death or serious injury Warning If the machine is operated incorrectly death or serious injury may result Caution If the machin...

Страница 4: ...arning label locations Warning labels are attached to the positions of the firefighting pump as shown below If the labels are peeled off or damaged please order new ones telling the part No as shown f...

Страница 5: ...be caught by the machine or slip and fall and injured Warning Do not operate the firefighting pump if you cannot concentrate your attention on operation as you are drunken fatigued sick or under influ...

Страница 6: ...o not observe the instruction The fuel may catch fire and explode Danger When supplying fuel do not allow the fuel level to exceed the F mark If fuel spills wipe away immediately and do not bring that...

Страница 7: ...the pump If you do not observe the instruction They may be beaten by your elbow or the rope and injured Danger Before replenishing the fuel during operation wait until the engine cools down enough If...

Страница 8: ...clothes or assets may be damaged Caution Before starting inspections or service stop the engine and wait until it cools down sufficiently If you do not observe the instruction You may be hurt or burn...

Страница 9: ...7 2 Name of components Recoil starter side Operating side...

Страница 10: ...8 2 Name of components Pump side Non operation side...

Страница 11: ...he main unit is covered with a thin vinyl cover Be sure to remove it before operating the machine 2 Mounting the battery 1 Fix the battery with the supplied rubber band to the battery box 2 Connect th...

Страница 12: ...and explode After supplying fuel close the fuel tank cap securely If not the fuel may catch fire and explode 2 Supply 2 cycle engine oil tank capacity 0 4L The fire pump is a separate filling type Su...

Страница 13: ...below the water level If it is positioned above the specified level air may be sucked preventing water discharging 3 Arrange the pump so that the water suction height is 3 m or less as low as possibl...

Страница 14: ...uld be suited to work Wear a helmet shoes with creepers and clothes without looseness You may be caught by the machine or slip and fall and get injured 3 Do not operate the firefighting pump when you...

Страница 15: ...the tickler button for several seconds while the engine is cold will facilitate the engine start When the engine is still warm after the operation never press the tickler If the engine is not started...

Страница 16: ...the switch 4 When using the rope to start the engine pull the recoil starter handle forcibly In case an engine does not start so well due to an excessive fuel like after running for warm up turn off...

Страница 17: ...ressure with the throttle dial depending on the situation of the fire site Keep the pointer on the pressure gauge and compound gauge in the green range when discharging the water 2 By inserting the se...

Страница 18: ...irefighting pump was operated much water remains inside If the water is left in the pump rust may be generated or the pump may be damaged due to frozen water in the cold season Be sure to drain water...

Страница 19: ...touches the plug in fixture male screw While the plug in type intermediate fixture is used while water is being discharged never touch the pushing ring If the pushing ring is pushed in while the wate...

Страница 20: ...tes satisfactorily when required next time or to secure its long life 1 Environment Place the pump at a dry and cool place avoiding dust or direct sun beams 2 Supply fuel and lubricating oil to specif...

Страница 21: ...t be removed until the water in the hose is drained after the water is discharged 2 Operation Necessary an operator for all of pump each 1 Open the water discharge valve or all sub pump in advance 2 S...

Страница 22: ...er supply Avoiding from any damage of the suction hose with the higher water pressure choose a fire hose only with a coupler for hose connected Before connection with the hose discharge some water fro...

Страница 23: ...send water sucked from the hydrant to the next pump Start the engines for the next following pumps Check the pressure scale of the last pump and increase the engine speed for the proper pressure and d...

Страница 24: ...in a warm room Do not use fire to malt the frozen water The fuel may catch the fire and explode 2 Starting the engine 1 Immediately after the engine is started the operation may not be smooth Idle the...

Страница 25: ...Changing fuel in tank Cleaning of ignition plug Inspection of V belt Starting and vacuum test Water suction and discharge test Caution Above table indicates inspection timing under general operating c...

Страница 26: ...connecting connect the cord first If not short circuit may occur and cause a fire or burn you B Auxiliary charge Battery charging level decreases day by day due to self discharge even if the battery i...

Страница 27: ...eeds and the charging state reaches 80 or more the green LED comes on timer charge starts If the charging is continued in this state the red LED comes off to indicate the full charge state and this st...

Страница 28: ...rror cause and close the circuit breaker after 60 seconds The output connector is loose Seat the output connector all the way and lock it securely The battery is obviously in a discharged state but th...

Страница 29: ...quality always clean the water suction strainer A Remove the cap of the strainer B Pull out the strainer and wash away dust sand and other foreign materials cleanly in water C Wash the recess for the...

Страница 30: ...t cap B Close the pump drain cock C Start the engine and pull the suction lever D When the indicator of the compound gauge does down to 0 05MPa return the suction lever and stop the engine E If the po...

Страница 31: ...combustion chamber but engine does not start 1 Overflow excessive fuel 2 Tickler is abused excessive fuel 3 Choke is closed all the way auto choke 4 Fuel is not volatile old 5 Fuel is mixed with mois...

Страница 32: ...ual sound Mechanical sound 1 Flywheel is loose 2 Skirt is hit by because of worn piston 3 Internal contact of armature plate 4 Foreign matter in crankcase 5 Impeller hits foreign matter or is in conta...

Страница 33: ...is abnormal 1 Air is sucked because suction pipe is not tightened properly 2 Air is sucked from top end of suction pipe 3 Drain cock is left open 4 Mechanical seal is faulty 5 Water discharge valve is...

Страница 34: ...time is short 3 Engine speed is low 4 V belt slips 5 Vacuum pipe or strainer is clogged 6 Suction strainer is clogged 7 Suction head is large 1 Check and repair 2 Prolong operation time 3 Adjust to st...

Страница 35: ...is deteriorated 2 Wiring is short circuited 3 Charging is poor 4 Switch operation is wrong 1 Replace 2 Repair short circuited part 3 Recharge 4 Operate properly Wiring faulty Wiring is burnt 1 Battery...

Страница 36: ...essure 0 273 m3 min Pump pressure Normal 0 5 High pressure 0 7 Nozzle diameter Normal 18 5 High pressure 12 5 Speed or revolution Normal 5200 rpm High pressure 5500 rpm Water inlet Nominal 65 fire eng...

Страница 37: ...For 2 cycle engine Starting method Starting motor recoil starter Fuel Regular automotive gasoline Ignition method No contact magneto CD ignition type Ignition plug NGK B6HS Fuel consumption 4 6L Fuel...

Страница 38: ...36 7 Wiring diagram...

Страница 39: ......

Страница 40: ...K20000120 0 2018 9 Printed in Japan...