background image

EXPLODED VIEW AND TOOLS

11

13

12

2

3

8

9

4

7

6

1

5

10

2

Tools required:

Drill/Screwdriver

Mallet

Hack saw

Tools included:

Spanner

Torx bit

ITEM 

NO.

PART NAME

DRG NUMBER

LENGTH

Default/QTY.

1

S1 - Full Frame - SR

S1

Default

6

2

P1

P1

Default

1

3

ST1 Roof Tie

ST1

Default

1

4

CB1 Bracket

CB1

Default

7

5

JF1 Bracket

JF1

Default

7

6

FT1 Bracket

FT1

Default

3

7

FT3 Bracket

FT3

Default

5

8

RB1 Bracket

RB1

Default

8

9

R2

R2

Default

3

10

Seasling Strip -  

2195mm

Sealing Strip

Default

4

11

PCE2

PCE1

Default

2

12

RC2 - 4059 RAD -

RC1

Default

3

13

2MD

2MD

2110

2

14

40x40 End cap

BOUGHT IN ITEM

40 x 40 x 

20

9

Содержание SR1554

Страница 1: ...Assembly Instructions Shelter type SR1554 SR1554 03 260916 UK Email Sales shelters4less co uk Web www shelters4less co uk Tel 0800 160 1002 ...

Страница 2: ...EXPLODED VIEW AND TOOLS 11 13 12 2 3 8 9 4 7 6 1 5 10 2 Tools required Drill Screwdriver Mallet Hack saw Tools included Spanner Torx bit ...

Страница 3: ...NO DESCRIPTION DIMENSION IMAGE QTY 1 S1 Frame 2000x1035 6 2 P1 Post 106x110x40 1 3 ST1 Roof Tie Trim To 2195 1 4 CB1 Bracket 2000x1035 7 5 JF1 Bracket 110x110x40 6 6 FT1 Foot Bracket 109x100x40 3 7 FT3 Foot Bracket 109x100x80 5 8 RB1 Bracket 110x46 8 9 R2 Rafter 2200x40x40 3 10 SS Sealing Strip 110x46 2 ROLLS 11 PCE2 Roof Panel 2205x1050 2 12 RC2 Roof Strip 2060x40x40 3 13 2MD Roof Edge Trim Trim ...

Страница 4: ...are aligned correctly Step 1 Assemble S1 frames to make up the main structure using CB1 brackets in the corners and JF1 brackets on straight joints Then attach P1 Post using one JF1 bracket Then attach ST1 Tie bar using a JF1 bracket and one CB1 bracket GENERAL NOTE THE 50 mm TECH SCREWS ARE FOR FIXING ROOF STRIPS RC ONLY ...

Страница 5: ...1035 FRONT VIEW R2 RB1 FT1 FT2 Step 2 Move shelter in to its final position make sure everything is square and secure to the floor using FT1 and FT3 foot brackets Attach R2 roof rafters using RB1 brackets 5 ...

Страница 6: ...S sealing strips to the rafters two for cental rafter and line up the PCE2 roof panels to the outside of the shelter leaving a gap between them Apply more sealing strips to the top of the roof panel directly above the first strips 6 ...

Страница 7: ...D2 Step 4 Apply RC2 strips on top of the panels and use 50mm Tech screws to secure them in place Then clip on the 2MD edge trim to the bottom of the roof panels Then fit the Black plastic caps on exposed nuts and bolts Fit the square plastic end caps to any open ends of box sections 7 ...

Страница 8: ...1044 50 1035 1044 50 1035 1044 50 1136 50 1035 995 2181 2181 Ground anchor positions and overall size Suggested concrete base size 200mm oversized on all four sides Scale 1 15 8 ...

Страница 9: ...NOTES 9 ...

Страница 10: ...NOTES 10 ...

Страница 11: ...NOTES 11 ...

Страница 12: ...ularly with soapy water Ensure all fittings are tight for example after a big storm Touch up any exposed metal should it get scratched CONTACT DETAILS Email Sales shelter4less co uk Web www shelters4less co uk Tel 0800 160 1002 Shelters4Less Unit 3 2 Landsdowne Crescent Bournemouth BH1 1SA All Parts and Fixings checked by Print Name Signature ...