Shearwater DiveCAN
®
Petrel
DocRevB
69
Specifications
Specification
DiveCAN
®
Rebreather Model
Operating Modes
Closed Circuit (CC)
Open Circuit (OC, for bailout)
Decompression Model
Bühlmann ZHL-16C with GF
VPM-B and VPM-B/GFS (optional)
Pressure (depth) sensor
Piezo-resistive
Range
0 Bar to 14 Bar
Accuracy
+/-20 mBar (at surface)
+/-100 mBar (at 14bar)
Crush Depth Limit
30 Bar (~290msw)
Surface Pressure Range
500 mBar to 1080 mBar
Depth of dive start
1�6 m of sea water
Depth of dive end
0�9 m of sea water
Operating Temperature Range
+4ºC to +32ºC
Short-Term (hours)
Temperature Range
-10ºC to +50ºC
Long-Term Storage
Temperature Range
+5ºC to +20ºC
Battery
AA Size, 0�9V to 4�3V
Recommended Battery Type
AA 1�5V Photo Lithium (e�g� Energizer Ultimate Lithium)
Battery Operating Life
(Display Medium Brightness)
35 Hours (AA 1�5V Alkaline)
55 Hours (AA 1�5V Photo Lithium)
100 Hours (SAFT LS14500)
External Connector
Hardwired cable to 5-pin DiveCAN® connector
(male pins)
Weight
0�4kg
Size (W X L X H)
84mm X 74mm X 38mm