User Manual
Страница 1: ...User Manual ...
Страница 2: ...ng 5 Mounting 6 Orientation 6 Rigging 6 Multi Bracket Mounting 7 4 Operation 8 Control Panel Operation 8 Menu Map 8 Configuration DMX 10 Starting Address 10 Static Mode 10 Auto Programs 10 Sound Active Mode 11 Sensitivity Mode 11 Master Slave 11 Dimmer Profiles 11 LED Frequency 12 Fan Mode 12 Back Light 12 DMX Fail 12 System Information 12 Factory Reset 12 DMX Channel Assignments and Values 13 8Ch...
Страница 3: ...er Chauvet has no obligation to make and does not commit to make any such revisions Download the latest version from www chauvetdj com The works of authorship contained in this manual including but not limited to all design text and images are owned by Chauvet Copyright 2018 Chauvet Sons LLC All rights reserved Electronically published by Chauvet in the United States of America CHAUVET the Chauvet...
Страница 4: ...e product is within the range stated on the decal or rear panel of the product The product is for indoor use only IP20 To prevent risk of fire or shock do not expose the product to rain or moisture Always install the product in a location with adequate ventilation at least 20 in 50 cm from adjacent surfaces Be sure that no ventilation slots on the product s housing are blocked Never connect the pr...
Страница 5: ...Page 3 of 18 Shocker 2 User Manual Rev 2 INTRODUCTION 2 INTRODUCTION Product Overview DMX In Out Fuse Holder Power In Out Menu Buttons LED Display Bracket Adjustment Knob Safety Loop Zone 2 Zone 1 ...
Страница 6: ...Page 4 of 18 INTRODUCTION Shocker 2 User Manual Rev 2 Product Dimensions 14 75 in 374 5 mm 6 in 153 mm 10 3 in 116 mm 3 8 in 96 mm 13 24 in 336 5 mm 12 2 in 309 5 mm ...
Страница 7: ... back of the product Please see the diagram below for further explanation Power Linking Diagram Always connect the product to a protected circuit a circuit breaker or fuse Make sure the product has an appropriate electrical ground to avoid the risk of electrocution or fire To eliminate unnecessary wear and improve its lifespan during periods of non use completely disconnect the product from power ...
Страница 8: ...duct can support the product s weight see the Technical Specifications When mounting the product overhead always use a safety cable Mount the product securely to a rigging point whether an elevated platform or a truss When rigging the product onto a truss use a mounting clamp of appropriate weight capacity When power linking multiple products mount the products close enough for power linking cable...
Страница 9: ...re banks with ease Link up to 2 products vertically from any mounting point Make sure the mounting clamps are capable of supporting the combined weight of the products For our CHAUVET line of mounting clamps go to http trusst com products Safety Cable such as CH 05 from Chauvet Bracket Adjustment Knob Expansion Bracket Mounting Bracket ...
Страница 10: ...r to find a higher value DOWN Press to scroll down the list of options or to find a lower value ENTER Press to activate a menu option or a selected value MODE PROGRAMMING LEVELS DESCRIPTION DMX Address 001 505 Selects DMX address DMX Channel 1Ch Sets 1 channel DMX mode and DMX starting address 2Ch Sets 2 channel DMX mode and DMX starting address 4Ch Sets 4 channel DMX mode and DMX starting address...
Страница 11: ...55 Auto 9 Dimmer 000 255 Speed 000 255 Auto 10 Dimmer 000 255 Speed 000 255 Auto 11 Dimmer 000 255 Speed 000 255 Auto 12 Dimmer 000 255 Speed 000 255 Auto 13 Dimmer 000 255 Speed 000 255 Auto 14 Dimmer 000 255 Speed 000 255 Sound Show Sound 1 Sound active programs 1 5 Sound 2 Sound 3 Sound 4 Sound 5 Sensitivity 000 100 Sound sensitivity low to high Master Slave Master Sets Master Slave mode Slave ...
Страница 12: ...Press ENTER 3 Use UP or DOWN to select the starting address from 001 506 4 Press ENTER Static Mode The Static mode allows for permanent dimmer and strobe presets without a DMX controller 1 Go to the Static main level 2 Select Dimmer or Strobe 3 Select the desired value 000 255 Auto Programs Auto programs allow for dynamic blinder effects without a DMX controller 1 Go to the Auto Show main level 2 ...
Страница 13: ...he master without a DMX controller To set each of the slaves 1 Go to the Master Slave main level 2 Select Slave 1 4 To set the master 1 Go to the Master Slave main level 2 Select Master 3 Select an auto program as explained in Auto Programs or a static setting Dimmer Profiles This setting determines how fast the output of the Shocker 2 changes when you modify the output value This setting provides...
Страница 14: ...on the Shocker 2 s display stays on after the last button is pressed on the control panel 1 Go to the Back Light main level 2 Select On remains on 10S 10 seconds 20S 20 seconds or 30S seconds DMX Fail These options determine what happens when DMX signal is lost or interrupted 1 Go to the main level 2 Select the DMX FAIL programming level 3 Select either HOLD holds the last received DMX input or BL...
Страница 15: ... program 10 181 197 Auto program 11 198 214 Auto program 12 215 231 Auto program 13 232 249 Auto program 14 250 255 Sound show program 4 6 Auto Speed 000 255 Speed slow to fast Sound Sensitivity 000 010 Sound sensitivity off 011 255 Sound sensitivity low to high 7 Master Slave Mode 000 006 No function 007 050 Master 051 100 Slave 1 101 150 Slave 2 151 200 Slave 3 201 255 Slave 4 8 Dimmer Speed Mod...
Страница 16: ...itivity low to high 7 Dimmer Speed Mode 000 051 Preset dimmer speed 052 101 Dimmer speed mode off 102 152 Dimmer speed mode 1 fastest speed 153 203 Dimmer speed mode 2 middle speed 204 255 Dimmer speed mode 3 slow speed CHANNEL FUNCTION VALUE PERCENT SETTING 1 Dimmer 000 255 0 100 2 White 1 000 255 0 100 3 White 2 000 255 0 100 4 Strobe 000 010 No function 011 255 Strobe slow to fast CHANNEL FUNCT...
Страница 17: ...instructions below 1 Unplug the product from power 2 Wait until the product is at room temperature 3 Use a vacuum or dry compressed air and a soft brush to remove dust collected on the external surface vents 4 Clean all transparent surfaces with a mild soap solution ammonia free glass cleaner or isopropyl alcohol 5 Apply the solution directly to a soft lint free cotton cloth or a lens cleaning tis...
Страница 18: ...A Power linking current products 8 A 6 products 8A 12 products Fuse T 2A 250 V T 2A 250 V POWER I O U S WORLDWIDE UK EUROPE Power input connector powerCON compatible powerCON compatible Power output connector powerCON compatible powerCON compatible Power Cord plug Edison U S Local Plug TYPE COLOR QUANTITY POWER CURRENT LIFESPAN LED COB LEDs 2 85 W 3 6 A 50 000 hours STROBE RATE BEAM ANGLE FIELD AN...
Страница 19: ... submit a service request online go to www chauvetdj com service request Send the merchandise prepaid in its original box and with its original packing and accessories Chauvet will not issue call tags Clearly label the package with the RMA number Chauvet will refuse any product returned without an RMA number Before sending the product clearly write the following information on a piece of paper and...
Страница 20: ...h chauvetlighting eu Brookhill Road Industrial Estate Pinxton Nottingham UK Website www chauvetdj eu NG16 6NT Voice 44 0 1773 511115 Fax 44 0 1773 511110 Benelux Address Stokstraat 18 Email BNLtech chauvetlighting eu 9770 Kruishoutem Belgium Website www chauvetdj eu Voice 32 9 388 93 97 France Address 3 Rue Ampère 91380 Chilly Mazarin Email FRtech chauvetlighting fr France Website www chauvetdj eu...