background image

Ionic
Breeze

® 

GP

SI730 Instructions

INCLUDES IMPORTANT

SAFETY INFORMATION

READ ALL INSTRUCTIONS 

BEFORE USING THIS

APPLIANCE

SAVE THESE 

INSTRUCTIONS

Содержание Ionic Breeze GP SI730

Страница 1: ...Ionic Breeze GP SI730 Instructions INCLUDES IMPORTANT SAFETY INFORMATION READ ALL INSTRUCTIONS BEFORE USING THIS APPLIANCE SAVE THESE INSTRUCTIONS ...

Страница 2: ... to be damaged If the appliance is not working properly or has been dropped damaged left outdoors or dropped into water return it to a service center or to the original place of purchase Do not pull lift or carry by the power cord Do not use the cord as a handle close a door on the cord or pull the cord around or against sharp edges or corners Keep the cord away from heated surfaces WARNING To red...

Страница 3: ...nit from outlet Do not unplug by pulling the cord Grasp the plug itself not the cord when unplugging from an outlet Do not handle the plug or appliance with wet hands Do not put any object into openings Do not continue to use with any opening blocked Keep all openings free of dust lint hair or anything that may reduce airflow Keep hair loose clothing fingers and all parts of the body away from ope...

Страница 4: ...y CAUTION This product generates invisible ultraviolet light To avoid overexposure when the lamp is on persons must stay at least one foot away from the unit if the total duration of exposure to the unit will be more than 1 hour per day Shorter durations of exposure at close proximity are safe If the enclosure is damaged do not use the product Never stare at the U V lamp or place your face directl...

Страница 5: ...movable collection grid with a damp cloth paper towel or sponge It is very important that the collection grid be allowed to dry completely before returning it to the main housing What is the clean fresh scent I smell This scent is ozone O3 a combination of three oxygen atoms The U S government has set safe standards for ozone and the Ionic Breeze complies with those standards Which power setting s...

Страница 6: ...ings for details 12 Set Up and Operation Switch the MODE CONTROL to the desired setting ON The unit will clean and circulate the air but the germicidal lamp is not activated ON G P Air is also passed through UV light produced by a germicidal lamp B o o s t O f f O n O n G P L o M e d C L E A N MODE CONTROL Blue Glow coming from within the unit indicates that the germicidal lamp is operating ...

Страница 7: ...wer level will resume after the five minutes has elapsed Switch the POWER CONTROL to the desired HI MED or LO setting Normal operation at all power levels involves a pre programmed cycle of alter ing high and low air move ment B o o s t O f f O n O n G P L o M e d H i C L E A N BOOST B o o s t O f f O n O n G P L o M e d H i C L E A N POWER CONTROL ...

Страница 8: ...hree collection bars Invert the entire unit for two or three times before replacing the grid Cleaning the grid every one or two weeks As a reminder the cleaning indicator light will turn amber after two weeks If the cleaning indicator light turns red the unit has shut down because of excessive dirt or circuitry problems In most cases a thorough cleaning will return the unit to normal operation COL...

Страница 9: ...urs before returning to unit Use a compressed gas dusting product to remove any accumulated particles from the ionizing wires and to blow out any dust that is settled in the base of the unit Because of the dust it is advisable to do this outside If the unit makes noise during operation a thorough cleaning of the grid and ionizing wires may be required ...

Страница 10: ...nit will not function while the collection grid is removed and or the germicidal lamp cover is removed The Ionic Breeze has been independently tested and found to comply with U S government limits on the maximum acceptable level of ozone less than 50 parts per billion by volume of air circulating through the device Persons with a history of asthma heart disease or any lung disease or breathing pro...

Страница 11: ...continuous use Replace earlier if there is no blue glow inside the housing when the unit is running in G P mode Oil from fingers will reduce the germicidal performance of the U V lamp DO NOT allow fingers to come in contact with the glass Use gloves or handle only by the metal area of the lamp If you touch the lamp or need to clean it for any reason wipe with a paper towel dampened with alcohol or...

Страница 12: ...s and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception whichcanbedeterminedbyturningtheequipmentoffandon theuserisenco...

Страница 13: ...fects in materials or workmanship In the event repair is not possible The Sharper Image will either replace this product with one of similar features and price or refund the full purchase price of the product whichever you prefer How to Obtain Service Return the product and receipt along with a brief explanation of the problem to T S I Returns Department 2901 A West 60th Street Little Rock AR 7220...