UX-P115U
2 – 20
[3] Troubleshooting
Refer to the following actions to troubleshoot any of the problems
mentioned in 1-4.
[1] A communication error occurs.
[2] Image distortion produced.
[3] Unable to do overseas communication.
[4] Communication speed slow due to FALLBACK.
• In crease the transmission level SOFT SWITCH A4-1, 2, 3, 4, 5.
May be used in case [1] [2] [3].
• Decrease the transmission level SOFT SWITCH A4-1, 2, 3, 4, 5.
May be used in case [3].
• Apply line equalization SOFT SWITCH A2-1, 2, 3, 4.
May be used in case [1] [2] [3] [4].
• Slow down the transmission speed SOFT SWITCH A2-1, 2, 3, 4.
May be used in case [2] [3].
• Replace the TEL/LIU PWB.
May be used in all cases.
• Replace the control PWB.
May be used in all cases.
• If transmission problems still exist on the machine, use the follow-
ing format and check the related matters.
TO:
ATT:
Ref.No. :
CC:
ATT:
Date
:
FM:
Dept
:
Sign
:
* Please complete this report before calling the "TAC" hotline if problem still occurs.
***** Facsimile communication problem *****
Ref.No.:
Date:
From: Mr.
Fax Tel No.:
Our customer
Name
Tel No.
Address
Fax No.
Contact person
Model name
Other party
Name
Tel No.
Address
Fax No.
Contact person
Model name
Problem mode
Line: Domestic / international
Model:
G3
Phase: A, B, C, D.
Reception / Transmission
Automatic reception / Manual reception
Automatic dialing / Manual dialing / Others
Frequency:
%
ROM version:
Confirmation
item
Please mark problem with an X.
No problem is: 0.
A1 A2 B1 B2 C1 C2
D1 D2 E1 E2
Transmission level setting is (
) dB at our
customer
Transmission level (
) dBm
Reception level (
) dBm
By level meter at B1 and B2
Comment
**** Please attach the G3 data and activity report on problem. ****
Countermeasure
Our customer
Our service
A1
A2
C1
D2
B1
B2
E1
E2
C2
D1
Other party
Other party's service
Содержание UX-P115
Страница 60: ...UX P115U 6 7 7 Control PWB parts layout Top side ...
Страница 61: ...UX P115U 6 8 8 Control PWB parts layout Bottom side ...
Страница 63: ...UX P115U 6 10 2 TEL LIU PWB parts layout Top side The TEL LIU PWB of the model employs lead free solder ...
Страница 64: ...UX P115U 6 11 3 TEL LIU PWB parts layout Bottom side The TEL LIU PWB of the model employs lead free solder ...
Страница 66: ...UX P115U 6 13 2 Power supply PWB parts layout Top side 3 Power supply PWB parts layout Bottom side ...
Страница 76: ...UX P115U 8 5 MEMO ...