background image

5

R-209EKA

SCHEMATIC

NOTE: CONDITION OF OVEN

1.

DOOR CLOSED

2.

CLOCK APPEARS ON DISPLAY

NOTE: "   " indicates components with potential above 250V.

POWER 
TRANSFORMER

RECTIFIER

MAGNETRON

CAPACITOR
0.86

µ

F

C/T FUSE

120V AC
60 Hz

OVEN
LAMP

TURN-
TABLE
MOTOR

FAN 
MOTOR

MONITOR 
SWITCH

SECONDARY
INTERLOCK
SWITCH

TTM

OL

FM

GRN

A3

COM.

N.O.

DOOR
SENSING
SWITCH

B1

B2

(RY-1)

(RY-2)

CONTROL UNIT

PRIMARY
INTERLOCK
RELAY

MAGNETRON 
THERMAL CUT-OUT

A1

TEST PROCEDURES

PROCEDURE

LETTER

COMPONENT TEST

Figure O-1. Oven Schematic-Off Condition

OPERATION

DESCRIPTION OF OPERATING SEQUENCE

POWER OUTPUT REDUCTION

If the oven is set for more than 20 minutes at 80, 90 or 100%
power level, after the first 20 minutes the power level will
automatically adjust itself to 70% power to avoid overcook-
ing.

B

POWER TRANSFORMER TEST

1. Disconnect the power supply cord, and then remove outer case.
2. Open the door and block it open.
3. Discharge high voltage capacitor.
4. Disconnect the primary input terminals and measure the resistance of the transformer with an

ohmmeter. Check for continuity of the coils with an ohmmeter. On the R x 1 scale, the resistance of
the primary coil should be less than 1 ohm and the resistance of the high voltage coil should be
approximately 132 ohms; the resistance of the filament coil should be less than 1 ohm.

5. Reconnect all leads removed from components during testing.
6. Reinstall the outer case (cabinet).
7. Reconnect the power supply cord after the outer case is installed.
8. Run the oven and check all functions.

(HIGH VOLTAGES ARE PRESENT AT THE HIGH VOLTAGE TERMINAL, SO DO NOT ATTEMPT TO
MEASURE THE FILAMENT AND HIGH VOLTAGE.)

Содержание R-209EKA

Страница 1: ...producing very high voltage and current contact with following parts may result in a severe possibly fatal electrical shock High Voltage Capacitor High Voltage Power Transformer Magnetron High Voltage Rectifier Assembly High Voltage Harness etc SHARP CORPORATION This document has been published to be used for after sales service only The contents are subject to change without notice SUPPLEMENTAL S...

Страница 2: ...transmission systems shall be repaired replaced or adjusted by procedures described in this manual before the oven is released to the owner e A microwave leakage check to verify compliance with the Federal Performance Standard should be performed on each oven prior to release to the owner BEFORE SERVICING Before servicing an operative unit perform a microwave emission check as per the Microwave Me...

Страница 3: ...acitor 4 Disconnect the leads to the primary of the power transformer 5 Ensure that the leads remain isolated from other components and oven chassis by using insulation tape 6 After that procedure reconnect the power supply cord When the testing is completed 1 Disconnect the power supply cord and then remove outer case 2 Open the door and block it open 3 Discharge high voltage capacitor 4 Reconnec...

Страница 4: ...initially at 20 5 C 68 F in the center of the oven cavity The water container shall be a low form of 600 ml 20 oz beaker with an inside diameter of approx 8 5 cm 3 1 2 in and made of an electrically nonconductive material such as glass or plastic The placing of this standard load in the oven is important not only to protect the oven but also to insure that any leakage is measured accurately 4 Set ...

Страница 5: ...ntil the following points are ensured A The door is tightly closed B The door brackets and hinges are not defective C The door packing is not damaged D The door is not deformed or warped E There is no other visible damage with the oven Servicing and repair work must be carried out only by trained service personnel DANGER Certain initial parts are intentionally not grounded and present a risk of el...

Страница 6: ...oking Repetition Rate P HI Full power throughout the cooking time P 90 approx 90 of FULL Power P 80 approx 80 of FULL Power P 70 approx 70 of FULL Power P 60 approx 60 of FULL Power P 50 approx 50 of FULL Power P 40 approx 40 of FULL Power P 30 approx 30 of FULL Power P 20 approx 20 of FULL Power P 10 approx 10 of FULL Power P 0 No power throughout the cooking time POPCORN pad MINUTE PLUS pad REHE...

Страница 7: ...atically adjust itself to 70 power to avoid overcook ing B POWER TRANSFORMER TEST 1 Disconnect the power supply cord and then remove outer case 2 Open the door and block it open 3 Discharge high voltage capacitor 4 Disconnect the primary input terminals and measure the resistance of the transformer with an ohmmeter Check for continuity of the coils with an ohmmeter On the R x 1 scale the resistanc...

Страница 8: ...k R5 1k HZ4C3 ZD1 C3 0 01µ 25v C40 0 01µ 25v C5 0 1µ 25v C6 0 1µ 25v C7 0 1µ 25v C4 S12 SEG19 VC3 B Z R00 R01 R02 R03 P20 P21 P22 P23 K00 K01 K02 K03 COM0 COM1 VC2 VC1 SEG18 SEG17 SEG16 SEG15 SEG14 SEG13 S11 S10 S 9 S 8 S 7 S 6 S 5 S 4 S 3 S 2 S 1 C 1 C 2 C 3 0 01µ 25v C11 0 01µ 25v SP1 PKM22EPT D20 J1 D21 RY2 AC120V 60Hz OVEN LAMP TURNTABLE MOTOR FAN MOTOR DOOR SENSING SWITCH MICRO AC H GND J15 4...

Страница 9: ... GDAI A304WRW0 Bottom plate 1 AF 2 3 GLEGPA074WRE0 Foot 2 AC CONTROL PANEL PARTS 3 1 DPWBFC196WRUZ Control unit 1 BD 3 2 FPNLCB543WRKZ Control panel frame with key unit and LCD 1 BD 3 2 1 FUNTKB036WREZ Key unit 1 AV 3 3 QCNC A013WRZZ Rubber connector 1 AE 3 4 RLCDSA089DRZZ Liquid crystal display 1 AM 3 5 XEPSD30P08XS0 Screw 3mm x 8mm 3 AA OVEN PARTS 4 1 PHOK A105WRF0 Latch hook 1 AL 4 2 LANGQA530W...

Страница 10: ...n 1 AD SCREWS AND WASHERS 7 1 XHPSD40P08K00 Screw 4mm x 8mm 2 AA 7 2 LX EZA042WRE0 Special screw 2 AB 7 3 LX WZA028WRE0 Special washer 1 AB 7 4 XHTSD40P12RV0 Screw 4mm x 12mm 1 AA 7 5 XHTSD40P08RV0 Screw 4mm x 8mm 5 AA 7 6 XHPSD30P06000 Screw 3mm x 6mm 1 AA 7 7 LX CZ0052WRE0 Special screw 2 AA 7 8 XOTSD40P12000 Screw 4mm x 12mm 12 AA 7 9 XOTSF40P08000 Screw 4mm x 8mm 4 AA 7 10 LX CZA070WRE0 Specia...

Страница 11: ...7 8 2 1 7 8 7 10 7 10 7 9 7 5 7 5 A 4 6 4 4 4 9 7 1 7 8 7 7 4 10 7 1 1 4 7 8 7 8 7 8 4 1 2 2 2 3 7 8 7 8 7 8 4 13 2 3 7 2 4 16 7 3 1 10 1 11 7 5 7 4 1 3 1 7 7 6 1 1 1 1 1 2 1 6 4 3 1 5 7 9 7 11 1 8 6 9 6 8 1 2 7 8 4 3 4 14 4 14 4 7 4 11 6 2 6 1 4 15 4 8 6 7 4 5 4 12 4 17 A 7 12 1 9 4 2 4 18 ...

Страница 12: ...Control panel foil side of Control unit must be cleaned by ethyl alcohol MISCELLANEOUS CONTROL PANEL PARTS DOOR PARTS 2001 SHARP CORP 7S1 700E Printed in U S A COPYRIGHT 2001 BY SHARP CORPORATION ALL RIGHTS RESERVED No part of this publication may be reproduced stored in retrieval systems or transmitted in any form or by any means electronic mechanical photocopying recording orotherwise withoutpri...

Отзывы: