INSTALLATION MANUAL -PHOTOVOLTAIC MODULES-

 

 

1. INSTALLATION 

The mounting method has been verified by SHARP and NOT 

CERTIFIED  by  a  third  party  organization.  Please  review  the 
descriptions and drawings carefully; not mounting the modules 
according  to  one  of  these  methods  may  void  your  guaranty. 
These mounting methods are designed to allow module loading 
of 2400Pa.

 

 

 

 

 

 

Mounting Using Clips: Clamping on Longer Frame (Figure2) 

The modules can be mounted using clips (clamps) designed for solar 

modules as defined in the following Figures. Note that the mounting clips 

should meet the required dimensions as defined in the Figure1. Note that 

the CLIP CENTER POSITION (e) is important as specified in the Figure2. 

The module must be supported on the array system and should overlap 

the array rail by at least 10mm. The array rails (see pointillist image, row 

or  vertical  row)  must  support  the  bottom  of  the  frames  and  must  be 

continuous piece (no breaks in the rail).  

 

 

2. ELECTRICAL INSTALLATION INSTRUCTION

 

CABLE requirement

 

Conductor size:  4.0mm

2

,  

Cable type: XLPE cable (H1Z2Z2-K cable) 
Maximum DC voltage: 1.5kV 
Rating temperature: -40°C to +90°C,  

 
 
 
 
 
 
 
 
 

 

 

Module configuration (Recommend) 

# Maximum series configuration: please refer to Table-1 
(This value is calculated under the condition of Voc at -40 °C.) 
 
# Maximum parallel configuration: (Parallel connection of each 
string shall be conducted with following two options. Any other 
parallel connections are prohibited.) 
a)  Case  of  using  the  diodes;  1  diode  per  maximum  2  parallel 
strings  (Connect  a  diode  or  more  in  series  for  every  string  or 
every  2  parallel  strings  for  protection  of  module  from  reverse 
current over load.) 
b) Case of using the fuses; 1 fuse per every string (Connect a 
fuse for every single string for protection of module from reverse 
current over load.) 

 
CONNECTOR requirement 

The module shall be mated to the same connectors; 
Type: MC4 
Brand: Staubli Electrical Connectors 
 

3. WARNING 

Keep  all  MODULES  and  electriacal 
CONNECTORS  clean  &  dry  before 
installation. 
 

4. Disposal 

 

Dispose  photovoltaic  modules  properly. 
For Information about the proper disposal, 
contact your local recycling site 
 

 
 
 
 
 
 
 

    

 

 
 

 
 

ELECTRICAL OUTPUT AND THERMAL CHARACTERISTICS 

 

Rated electrical characteristics of Isc, Voc, are within ±10 percent of the indicated values and +5/-0 percent of Pmax (power measurement tolerance: ± 3%), 

under STC (standard test conditions) (irradiance of 1000 W/m

2

, AM 1.5 spectrum, and a cell temperature of 25 °C (77°F)).  

 

Table-1. Electrical characteristics (at STC)

Model

name

Maximum

Power

(Pmax)

Tolerance

Open-Curcuit

Voltage

(Voc)

Short-Circuit

Current

(Isc)

Voltage at point
of max. Power

(Vmpp)

Current at point

of max. Power

(Impp)

Maximum

system voltage

Over-Current

Protection

Application

Class

Maximum series

configuration(*)

NU-AH370

370W +5%/-0%

47.8V

9.97A

39.4V

9.39A

1,000V

15A

A

17

NU-AH360

360W +5%/-0%

47.4V

9.81A

39.0V

9.23A

1,000V

15A

A

17

* The maximum series number of modules depends on the local conditions. These values are calculated under the condition of Voc at -40 °C. 

 
Under normal conditions, a photovoltaic module is likely to experience conditions that produce more current and/or voltage than 

reported at Standard Test Conditions. Accordingly, the values of Isc and Voc marked on this module should be multiplied by a 
factor of 1.25 when determining component voltage ratings, conductor capacities, fuse sizes and size of controls connected to the 
module output. 
 

Application Class 

This module is rated as “Application class A” according to 

IEC61730.  
“Application class A” means: General access, hazardous 
voltage, hazardous power applications; Modules rated for 
use  in  this  application  class  may  be  used  in  systems 
operating at greater than 50V DC or 240W, where general 

contact  access  is  anticipated.  Modules  qualified  as 
“Application  class  A”  according  to  IEC  61730  are 
considered to meet the requirements for safety class II. 
 

FIRE RATING 

This module is rated as “Fire safety class C” according to 
IEC61730.

 
 
 

250 mm  < 

e

 < 400 mm  

e

 : span from module corner to clip center 

 

Figure2. Clamping on longer Frame 

 
 

Figure1. Clips (Clamps) requirement 
   1) Clip: Al alloy, 3mm Min. thickness 
   2) Catch length (50mm Min.) 
   3) Covering depth (7mm Min. on the frame) 
   4) Supporting depth (10mm Min.) 
   5) Frame 
      (applicable to all frame sections) 
   6) Array rail  
      (applicable to parallel or crossed mounting) 

 

Figure2. Clamping on longer Frame 

NU-SA***:  207mm (8.2in) < e < 330mm (12.9in) 
NU-SC***:  250mm (9.9in) < e < 400mm (15.7in) 
ND-RB***:  207mm (8.2in) < e < 330mm (12.9in) 

Содержание NU-AH370

Страница 1: ...dically remove any overhanging snow and or ice from the module framework as it may cause deformation of the module frame GENERAL INSTRUCTIONS 1 INTRODUCTION This Installation Manual contains essential information for the electrical and mechanical installation that you must know before installing SHARP PV modules This also contains safety information you need to be familiar with All the information...

Страница 2: ...In case of parallel connection please be sure to take proper measure e g fuse for protection of module and cable from over current and or blocking diode for prevention of unbalanced strings voltage to block the reverse current flow The current may easily flow in a reverse direction 20 Keep modules away from children HANDLING SAFETY 1 Do not cause an excessive load on the surface of PV module or tw...

Страница 3: ...rame grounding must consider the local requirement and regulation at the installation site When grounding is required please refer to below example connection Figure 3 Please be careful in arranging the system ground so that the removal of one module from the circuit will not interrupt the grounding of any other modules The modules should be grounded to the same electrical point as described below...

Страница 4: ...ic modules properly For Information about the proper disposal contact your local recycling site ELECTRICAL OUTPUT AND THERMAL CHARACTERISTICS Rated electrical characteristics of Isc Voc are within 10 percent of the indicated values and 5 0 percent of Pmax power measurement tolerance 3 under STC standard test conditions irradiance of 1000 W m2 AM 1 5 spectrum and a cell temperature of 25 C 77 F Tab...

Отзывы: