- 6 -                                                                    Installation Manual for PV modules 

C) ELECTRICAL INFORMATION 

 
ELECTRICAL RATINGS 

Rated electrical characteristics are within ±10 percent of the indicated values of Isc, Voc and 10/-5 percent of Pmax under Standard Test 

Conditions (irradiance of 100 mW/cm

2

, AM 1.5 spectrum, and a cell temperature of 25˚C (77˚F)). The warranty conditions are specified elsewhere in 

this manual. 

 
 

ND-U230C1 ND-U224C1 ND-U216C1 

Maximum Power (Pmax) 

230.0 W 

224.0 W 

216.0 W 

Open-Circuit Voltage (Voc) 

37.0 V 

36.9 V 

36.7 V 

Short-Circuit Current (Isc) 

8.24 A 

8.07 A 

7.85 A 

Voltage at maximum power (Vpmax) 

30.3 V 

30.2 V 

30.2 V 

Current at maximum power (Ipmax) 

7.60 A 

7.42 A 

7.16 A 

Maximum System Voltage 

600 V 

600 V 

600 V 

Minimum Blocking diode 

15 A 

15 A 

15 A 

Series Fuse 

15 A 

15 A 

15 A 

 

 
 

ND-224UC1 ND-220UC1 ND-216UC1 ND-208UC1 ND-200UC1 

Maximum Power (Pmax) 

224.0 W 

220.0 W 

216.0 W 

208.0 W 

200.0 W 

Open-Circuit Voltage (Voc) 

36.6 V 

36.5 V 

36.5 V 

36.3 V 

36.01 V 

Short-Circuit Current (Isc) 

8.33 A 

8.24 A 

8.10 A 

7.99 A 

7.90 A 

Voltage at maximum power (Vpmax) 

29.28 V 

29.19 V 

28.9 V 

28.71 V 

28.42 V 

Current at maximum power (Ipmax) 

7.66 A 

7.54 A 

7.48 A 

7.25 A 

7.04 A 

Maximum System Voltage 

600 V 

600 V 

600 V 

600 V 

600 V 

Minimum Blocking diode 

15 A 

15 A 

15 A 

15 A 

15 A 

Series Fuse 

15 

A 15 

A 15 

A 15 

A 15 

 

 
 

NT-175UC1 NT-170UC1 NE-170UC1 NE-165UC1 

Maximum Power (Pmax) 

175.0 W 

142.0 W 

170.0 W 

165.0 W 

Open-Circuit Voltage (Voc) 

44.4 V 

43.2 V 

43.2 V 

43.1 V 

Short-Circuit Current (Isc) 

5.40 A 

5.47 A 

5.47 A 

5.31 A 

Voltage at maximum power (Vpmax) 

35.4 V 

34.8 V 

34.8 V 

34.6 V 

Current at maximum power (Ipmax) 

4.95 A 

4.90 A 

4.90 A 

4.77 A 

Maximum System Voltage 

600 V 

600 V 

600 V 

600 V 

Minimum Blocking diode 

10 A 

10 A 

10 A 

10 A 

Series Fuse 

10 A 

10 A 

10 A 

10 A 

 

 

Under normal conditions, a PV module may produce more current and/or voltage than reported at Standard Test Conditions. Accordingly, the values 

of Isc and Voc marked on UL 1703 listed modules should be multiplied by a factor of 1.25 when determining component voltage ratings, conductor 

ampacities, fuse sizes and size of controls connected to the module output. Refer to Sec. 690-8 of the National Electric Code for an additional 

multiplying factor of 125 percent (80 percent de-rating) which may be applicable. Where Canadian UL listing applies, installation shall be in 

accordance with CSA C22.1, Safety Standard for Electrical Installations, Canadian Electrical Code, Part 1. 

 

Содержание ND-U230C1

Страница 1: ...thal shock whether the PV modules are connected or not 4 PV modules produce electricity when sufficient sunlight or other light source illuminates the module When modules are connected in series voltage is cumulative When modules are connected in parallel current is cumulative PV systems can produce high voltage and current which could present an increased hazard and may cause serious injury or de...

Страница 2: ...oves with padding in the palm and finger areas 14 Do not drop the PV module or allow objects to fall on the PV module 15 Do not lift the PV module by only one side The frame may bend Always use two hands to lift and carry the PV module on the long side of the frame 16 Some PV modules incorporate one or more support bars on the back of the module Do not mount or carry the PV module using the suppor...

Страница 3: ...ions below In a connection of this type the hardware such as a star washer must score the frame surface to make positive electrical contact with the frame The ground wire must not be smaller than No 14 AWG 2 1 mm2 and should be sized according to the NEC Hardware used must be compatible with the mounting structure material to avoid galvanic corrosion If using the SHARP On Energy mounting system th...

Страница 4: ...5 11 12 The modules may be mounted using clamps designed for solar modules as shown in Figures 5 Note that the clamp positions are important the clamp centerlines must be between 9 3 235 mm and 19 4 495 mm regarding ND series as shown in Figure 11 and 8 3 210mm and 18 5 470mm regarding NT NE series as shown in Figure 12 from the end of the module The module must be supported along the length of th...

Страница 5: ... s Figure 12 NT NE series Figure 9 ND series u u u u Figure 12 NT NE series Figure 9 ND series Figure 10 NT NE series 8 3 210 mm g 18 5 470 mm Figure 11 ND series 9 3 235 mm e 19 4 495 mm Figure 13 ND series 9 3 235 mm s 19 4 495 mm 8 3 210 mm u 18 5 470 mm Figure 14 NT NE series ...

Страница 6: ...m power Ipmax 7 66 A 7 54 A 7 48 A 7 25 A 7 04 A Maximum System Voltage 600 V 600 V 600 V 600 V 600 V Minimum Blocking diode 15 A 15 A 15 A 15 A 15 A Series Fuse 15 A 15 A 15 A 15 A 15 A NT 175UC1 NT 170UC1 NE 170UC1 NE 165UC1 Maximum Power Pmax 175 0 W 142 0 W 170 0 W 165 0 W Open Circuit Voltage Voc 44 4 V 43 2 V 43 2 V 43 1 V Short Circuit Current Isc 5 40 A 5 47 A 5 47 A 5 31 A Voltage at maxi...

Страница 7: ...nship and materials and Sharp agrees that for a period of one 1 year from the date of purchase by the consumer that Sharp will at its option either repair the defect or replace the defective Product or part thereof with a new or remanufactured equivalent at no charge to the purchaser for parts or labor for the period s set forth below Limited Warranty For Power The warranty period with respect to ...

Страница 8: ...improper voltage or power surges or abnormal environmental conditions such as acid rain or other pollution c the components in the construction base on which the module is mounted are defective d external corrosion mold discoloration or the like occurs e the product has been moved from its original installation f the model number or serial number of the product is altered removed or rendered illeg...

Отзывы: