Precautions for using lead-free solder

„

Employing lead-free solder

• “PWBs” of this model employs lead-free solder. The LF symbol indicates lead-free solder, and is attached on the PWBs and service manuals. The

alphabetical character following LF shows the type of lead-free solder. 

Example:

„

Using lead-free wire solder

• When fixing the PWB soldered with the lead-free solder, apply lead-free wire solder. Repairing with conventional lead wire solder may cause dam-

age or accident due to cracks.

As the melting point of lead-free solder (Sn-Ag-Cu) is higher than the lead wire solder by 40 

°

C, we recommend you to use a dedicated soldering

bit, if you are not familiar with how to obtain lead-free wire solder or soldering bit, contact our service station or service branch in your area.

„

Soldering

• As the melting point of lead-free solder (Sn-Ag-Cu) is about 220 

°

C which is higher than the conventional lead solder by 40 

°

C, and as it has poor

solder wettability, you may be apt to keep the soldering bit in contact with the PWB for extended period of time. However, Since the land may be
peeled off or the maximum heat-resistance temperature of parts may be exceeded, remove the bit from the PWB as soon as you confirm the
steady soldering condition.

Lead-free solder contains more tin, and the end of the soldering bit may be easily corroded. Make sure to turn on and off the power of the bit as
required.

If a different type of solder stays on the tip of the soldering bit, it is alloyed with lead-free solder. Clean the bit after every use of it.

When the tip of the soldering bit is blackened during use, file it with steel wool or fine sandpaper.

• Be careful when replacing parts with polarity indication on the PWB silk.

Lead-free wire solder for servicing

L

F a

Indicates lead-free solder of tin, silver and copper.

L

F a/a

Indicates lead-free solder of tin, silver and copper.

Part No.

Description

Code

ZHNDAi123250E

J

φ

0.3mm  250g (1roll) 

BL

ZHNDAi126500E

J

φ

0.6mm  500g (1roll)

BK

ZHNDAi12801KE

J

φ

1.0mm  1kg (1roll)

BM

Содержание LC-46XL2E

Страница 1: ...NTS No S58J8LC46XL2E MODEL LC 46XL2E S RU LCD COLOUR TELEVISION SUPPLEMENT In the interests of user safety Required by safety regulations in some countries the set should be restored to its orig inal condition and only parts identical to those specified should be used For this model the LCD panel module has been changed When servicing the product use this manual with the service manual LC 46XL2E S...

Страница 2: ...NTKE186FM01 DUNTKE186FM01 No Change N TERMINAL Unit DUNTKE187FM01 DUNTKE187FM01 No Change N R C LED Unit DUNTKE264FM01 DUNTKE264FM01 No Change N KEY Unit DUNTKE266FM01 DUNTKE266FM01 No Change N MIN IAV Unit DUNTKE188FM01 DUNTKE188FM01 No Change N ILLUMINATION Unit DUNTKE270FM01 DUNTKE270FM01 No Change N POWER Unit Unit Replacement Item RDENCA231WJQZ RDENCA231WJQZ No Change N AC INLET Unit Unit Rep...

Страница 3: ...e AC voltage drop across the resistor All checks must be repeated with the AC cord plug connection reversed If necessary a nonpolarized adaptor plug must be used only for the purpose of completing these checks Any reading of 1 05 V peak this corresponds to 0 7 mA peak AC or more is excessive and indicates a potential shock hazard which must be corrected before returning the monitor to the owner SA...

Страница 4: ...l lead solder by 40 C and as it has poor solder wettability you may be apt to keep the soldering bit in contact with the PWB for extended period of time However Since the land may be peeled off or the maximum heat resistance temperature of parts may be exceeded remove the bit from the PWB as soon as you confirm the steady soldering condition Lead free solder contains more tin and the end of the so...

Страница 5: ... for maintaining the safety and performance of the set This document has been published to be used for after sales service only The contents are subject to change without notice LC 46XL2E S RU PartsGuide 1 CABINET PARTS 2 LCD MODULE Assembly 3 SUPPLIED ACCESSOORIES CONTENTS No S58J8LC46XL2E MODEL LC 46XL2E S RU LCD COLOUR TELEVISION ...

Страница 6: ... 42 42 28 46 42 70 54 2 84 87 89 86 86 84 74 78 73 11 63 42 4 57 42 49 52 53 45 7 13 33 32 51 35 37 38 8 55 56 43 40 44 42 71 62 70 70 10 47 5 5 1 88 5 2 59 19 19 19 21 34 50 31 42 2 2 2 1 1 11 1 11 1 12 1 12 1 11 1 11 1 11 1 12 1 12 1 12 3 1 3 2 88 77 15 42 41 1 9 1 6 1 13 1 10 1 10 1 10 1 10 1 10 1 10 39 36 76 29 27 30 25 19 22 19 19 22 23 22 21 19 24 21 17 ...

Страница 7: ...W AV N R Main Radiator 26 PSLDMA702WJZZ AD R Conductiv Shield 10x20 x5 27 PSLDMB154WJQZ AD J 13x30x10 Gasket x2 28 PSLDMB327WJFW N R Main Shiled 29 PSPAZB312WJKZ AD N J Spacer 25 25 T2 0 30 PSPAZB313WJKZ AC J Spacer 20 20 T2 0 31 QCNCMA673WJZZ AG N J Connector B_To_B_Plug_80 32 QCNW F946WJQZ AH N R Connecting Cord AC POWERAC 33 QCNW G634WJQZ AN N R Connecting Cord PD MAINPOWER 34 QCNW F948WJQZ AK ...

Страница 8: ...41WJZZ AD P Terminal Sheet 78 PSHEPA543WJZZ AA S P Sheet for Boss x2 79 QCNW G012WJQZ AE N P Connecting Cord IL LEDILLU 80 RSP ZA347WJZZ AY N P Speaker L 81 RSP ZA348WJZZ AY N P Speaker R 84 XBPS740P10JS0 AA P Screw for Rear Cabinet x7 85 XEBS930P10000 AA J Screw for Bottom Cover x1 86 XEBS940P16000 AB J Screw for Rear Cabinet x14 87 TLABNC117WJZZ AC S Model Label 88 JBTN A676WJ1A AH P Control But...

Страница 9: ...LC 46XL2E S RU 5 2 LCD MODULE Assembly 1 9 19 19 17 13 22 22 34 18 10 10 16 12 15 14 11 20 35 30 30 28 26 24 22 21 3 4 23 9 21 6 7 8 2 32 33 31 7 3 ...

Страница 10: ...ZZ BF J INVERTER Unit D 15 PCOVPA087WJKZ AG J Invasion Prevention Cover A 16 PCOVPA088WJKZ AG J Invasion Prevention Cover B 17 PCOVPA089WJKZ AG J Invasion Prevention Cover C 18 PCOVPA090WJKZ AG J Invasion Prevention Cover D 19 LX LZA105WJZZ AB J Push Rivet x8 20 QCNW G150WJQZ AP J Cable 21 QSOCFA002WJZZ AD J Socket x44 22 LX BZA207WJF7 AA J Screw x13 for INVERTER Unit LCD CONTROL Unit 23 XBPS730P0...

Страница 11: ...77WJZZ AE P Guarrantee Card RU only X5 TGAN A801WJZZ AB P Guarrantee Card E only X6 TGAN A802WJZZ AC P AQUOS Care Plan E only X7 TINS D177WJN1 AQ N P Operation Manual ENGLISH X8 TINS D178WJN1 AQ N P Operation Manual SWEDISH X9 TINS D179WJN1 AH N P Operation Manual RUSSIAN X10 TINS D180WJN1 AS N P Operation Manual POLISH X11 CDAI A397WJ12 AQ N P Stand Ass y X12 TCAUHA337WJZZ AA N P ERRATTA Sheet E ...

Страница 12: ...y be reproduced stored in a retrieval system or transmitted in any from or by any means electronic mechanical photocopying recording or otherwise without prior written permission of the publisher SHARP CORPORATION AV Systems Group CS Promotion Center Yaita Tochigi 329 2193 Japan Jun 2008 TQ2536 S SH DS ...

Отзывы: