background image

4

7  VENTILATION SYSTEM

This Microwave Oven/Hood System is designed for adaptation to three types of hood ventilation 

systems. Select the type required for your installation.

A. RECIRCULATING—Non-Vented, Ductless Operation

  The unit is shipped assembled for recirculating.

NOTE:

1. The Exhaust Damper Assembly is not required for recirculating operation.
2. The Charcoal Filter should be replaced every 6 months, depending on use.
3. The Charcoal Filter is also sold as an accessory. See Operation Manual for ordering information.

B. Horizontal Ventilation System

Step 1.

*  Remove the screws (1) and (2) for opening 

the blower motor cover and save screws. 

Remove cover. See Figure 6.

Step 2.

*  Remove the screws (3) for Blower 

attachment and save screws. See Figure 7.

*  Lift blower unit out of mounting location. See 

Figure 8.

CAUTION:

 

Do not pull or stretch blower wiring.

Figure 7

Figure 8

Blower motor

Before : Fan blade openings facing Front

Blower motor cover

Back of OVEN

Figure 6

Содержание KOT1J0U

Страница 1: ...al care in the placement of the toggle bolts and top cabinet screws See Wall Template for details The top cabinet should be tested to ensure it is securely attached to the wall Place extra weight up to 110 pounds inside the top cabinet to test the support 2 x 4 Wood Studs 3 8 Dry Wall or Plaster lath 16 or 24 OVER THE RANGE MICROWAVE OVEN HOOD SYSTEM Please read all instructions thoroughly before ...

Страница 2: ...st be metal absolutely do not use plastic duct Check that all connections are made securely Please read the following carefully Exhaust connection The hood exhaust has been designed to connect to a standard 31 4 x 10 rectangular duct If round duct is required a rectangular to round adapter must be used Rear exhaust If a rear or horizontal exhaust is to be used care should be taken to align the exh...

Страница 3: ...ame Quantity Parts code 1 Lag screws 1 4 x 1 8 2 9KC7117604511 2 Toggle Bolts and Nuts 3 16 x 2 7 2 9KC3516003200 9KC3516003300 3 Cabinet Mounting Bolts 1 4 x 3 1 8 2 9KC7045607011 4 Washer 3 4 2 9KC3516003100 5 Nylon Grommet for metal cabinets 1 9KC3517503200 6 Damper 1 9KC3515400500 7 Mounting Plate 1 9KC351060009300 Lag screws 1 4 x 1 8 Toggle Bolts and Nuts 3 16 x 2 7 Cabinet Mounting Bolts 1 ...

Страница 4: ...d be replaced every 6 months depending on use 3 The Charcoal Filter is also sold as an accessory See Operation Manual for ordering information B Horizontal Ventilation System Step 1 Remove the screws 1 and 2 for opening the blower motor cover and save screws Remove cover See Figure 6 Step 2 Remove the screws 3 for Blower attachment and save screws See Figure 7 Lift blower unit out of mounting loca...

Страница 5: ...re 10 Parts B Step 3 Turn the blower unit so that the fan blade openings are facing back rear of unit See Figure 9 CAUTION Wires to blower unit must be routed properly to avoid pinching wires before reinstallation of cover plate Turn the blower motor clockwise 180 After Fan blade openings facing Rear Figure 9 Figure 10 ...

Страница 6: ... sliding it into the guides at the rear plate See Figure 12 13 Be sure that the damper hinge is on the top and the damper swings free into the wall outlet Damper Figure 12 Figure 13 Step 4 Place the blower unit into the opening and secure it to the oven with the screws 3 from step 2 See Figure 11 Figure 11 ...

Страница 7: ...ow Fan Top the blower motor and cover to the microwave oven with the screw 1 2 and 3 from step 1 and 2 See Figure 15 Carefully match the exhaust opening location of the microwave and attach the damper to blower motor cover by sliding it into the guides at the blower motor cover See Figure 16 17 Be sure that the damper hinge is on the front and the damper swings free into the wall outlet Fan Blade ...

Страница 8: ...h mounting plate at required locations and add the spring loaded toggles See Figure 19 Be sure you leave space at least the thickness of the wall between the mounting plate and the end of the toggle nut in closed position If you do not leave this space the toggle nut will not open on the other side of the wall 2 Position mounting plate on wall and insert toggle bolt assemblies through the drywall ...

Страница 9: ...Drill the holes following the instructions on the template Step 1 Protect the top of your range by placing a portion of the carton or some other heavy material over the cooking surface before mounting your oven Step 2 Lift the microwave oven and tilt it forward Hang the unit on two tabs at the bottom of the mounting plate See Figure 22 Step 3 Thread power cord through the hole at the bottom of the...

Страница 10: ...n the door See Figure 26 3 Slide the grille air to the left then pull it straight out 4 Push the charcoal filter backwards and remove it 5 Slide a new charcoal filter into place The filter should rest at the angle See Figure 27 6 Replace the grille air and 3 screws and close the door 7 Plug the oven in or turn on the power at the main power supply CHARCOAL FILTER GRILLE AIR Step 4 Then insert a bo...

Страница 11: ...d the Operation Manual 5 Keep the Installation Instructions for the local electrical inspector s use ACCESSORIES Check with your dealer or order directly from the SHARP Accessories and Supplies Center Call toll free 1 800 BE SHARP 237 4277 1 CHARCOAL FILTER 9KC35119 0000700 Filter is used when hood exhaust is recirculated only SHARP ELECTRONICS CORPORATION 100 Paragon Drive Montvale New Jersey 076...

Страница 12: ...1 13 _ 전체 포맷 신규 사진 및 일러스트 호환 작업 14 cut 18 07 27 5p 3p 7p 8p 9p 10p _ 7p 9p 페이지 삭제 18 08 13 4p 2p 7p 8p 11p 18 08 21 9p 1p 3p 4p 5p 6p 7p 9p 10p 11p _ 사진 및 일러스트 호환 작업 2 cut 18 08 22 2p 9p 10p 18 08 27 2p 5p 6p 18 08 28 1p 5p _ 박대형 님 18 08 31 2p 10p 11p _ 박대형 님 18 09 03 1p 10p _ 박대형 님 ABOUT THIS MANUAL 주 신광씨링 광주광역시 서구 하남대로 502번길 14 NO NEED PRINT ...