AR-5316 USER PROGRAMS 8-1
[8] USER PROGRAMS
The user programs allow the parameters of certain functions to be set, changed, or canceled as desired.
1. List of user programs
This copier has the following user programs.
*1 When the SPF is installed.
Program name
Program
No
Description
Default
Parameters
Auto clear time
1
"Auto clear time" automatically returns the copy settings to the initial
settings when a certain period of time elapses after a copy is made.
This program is used to select the period of time. "Auto clear time"
can also be disabled.
60sec
1 (OFF)
2 (10sec)
3 (20sec)
4 (60sec)
5 (90sec)
6 (120sec)
Preheat mode
2
This function automatically switches the machine to a low power
consumption state if the set duration of time elapses without the
machine being used when the power is on.
The POWER SAVE indicator lights up, however, the keys on the
operation panel can be used. Normal operation automatically
resumes when a key on the operation panel is pressed, a print job is
received or an original is placed.
1min
1 (1min)
2 (5min)
3 (30min)
4 (60min)
5 (120min)
6 (240min)
Auto power shut-off timer
3
This function automatically switches the machine to a state that
consumes even less power than preheat mode if the set duration of
time elapses without the machine being used when the power is on.
All lights except the POWER SAVE indicator and ON LINE indicator
go off. To resume normal operation, press the [START] key. Normal
operation also resumes automatically when a print job is received or
scanning is begun from a computer. While in auto power shut-off
mode, no keys (except the [START] key) can be used.
5min
1 (5min)
2 (30min)
3 (60min)
4 (120min)
5 (240min)
Stream feeding mode *
1
4
When copying using the SPF, during the period of time that the SPF
indicator blinks after an original has been scanned (about 5
seconds), a subsequent original can be placed and automatically
fed into the machine.
OFF
0 (OFF)
1 (ON)
Auto power shut-off
setting
5
Use this setting to enable or disable auto power shut-off.
ON
0 (OFF)
1 (ON)
Auditing mode
10
Use to enable or disable "Auditing mode".
"Auditing mode" is initially disabled.
OFF
0 (OFF)
1 (ON)
Account number entry
11
Use to set up account numbers.
Up to 20 accounts can be established.
-
-
Account number change
12
Use to change an account number.
-
-
Account number deletion
13
Use to delete an account number.
A single account number can be deleted, or all account numbers at
once.
Delete
single
account
0 (Delete single account)
1 (Delete all accounts)
Number of copies per
account
14
This displays the number of copies made by each account.
The maximum count is 49,999. If this number is exceeded, the count
will start over from 0.
-
-
Resetting account
15
Use to reset the copy count of an account to 0.
The copy count of a single account or of all accounts can be reset.
Reset single
account
0 (Reset single account)
1 (Reset all accounts)
Resolution in Auto/Text
mode
23
This setting is used to change the copy resolution in AUTO and
TEXT mode from 600 x 300 dpi to 600 x 600 dpi
(high-quality mode).
Scanning is slower when high-quality mode is used.
300dpi
1 (300dpi)
2 (600dpi)
[08]USERPROGRAMS.fm 1 ページ 2005年7月1日 金曜日 午後5時28分