background image

R

FU-40SE-J

FU-40SE-P

Tabletop / wall-mounting type

AIR PURIFIER
OPERATION MANUAL

Содержание FU-40SE-J

Страница 1: ...R FU 40SE J FU 40SE P Tabletop wall mounting type AIR PURIFIER OPERATION MANUAL ...

Страница 2: ......

Страница 3: ...LLATION E 3 NAMES OF PARTS E 4 ACCESSORIES E 5 INSTALLATION E 6 WHEN USING THE UNIT ON A TABLETOP E 6 WHEN USING THE UNIT WITH A MOUNTED WALL E 7 PREPARATION E 8 INSTALLING THE FILTERS E 8 INSERTING BATTERIES IN THE REMOTE CONTROL E 8 USING THE REMOTE CONTROL E 9 OPERATION E 10 MAIN UNIT OPERATION E 10 REMOTE CONTROL OPERATION E 11 CARE AND MAINTENANCE E 12 MAIN UNIT E 12 FILTERS E 12 GUIDE FOR LI...

Страница 4: ... the unit Cracking electrical shock and or fire may occur as a result Do not operate the unit when using indoor smoke generating insecticides Chemical ingredients may accumulate within the unit and then discharge from the exhaust port when the unit operates Discharge of such chemicals may be unhealthy to your body Do not allow the unit to intake flammable gases sparks from lit cigarettes incense e...

Страница 5: ... equip ment The remote control may become inoperative In this case move away from such lighting equipment or change direction Location exposed to direct sunlight The unit may not received signals from the remote control The unit may not respond to the signals of the remote control if the ends of fluorescent lighting become black or lights flicker due the depletion of service life however this is n...

Страница 6: ... antibacterial filter Stamina power carbon black Deodorization filter Pre filter Front panel Remote control Hook Stand Be sure to mount for tabletop instal lation Thumbscrew ABOUT THE CLEAN SIGN LAMP The dust sensor displays a clean sign depending on the relative change of the environment at the time the power plug is inserted in the wall outlet and after When the air is extremely dirty at the tim...

Страница 7: ...ate in the Clean mode Green light When the cluster ion operation is in the Refresh mode or AUTO cluster ion mode and the air in the room is clean the light turns on and the unit will operate in the Refresh mode Light off No cluster ions are generated If the lamp is bright when sleeping or if the ion generation noise is irritating turn off the cluster ion operation BACK Handle Exhaust port Power co...

Страница 8: ...tc The unit may fall and can be very dangerous When mounting the air purifier to the wall the mounted wall will become dirty as time passes To prevent this place a vinyl sheet etc around the unit A wall side to install is to choose the place to have the strength done firmly In the case of a wall or concrete wall with little strength request installation to a specialist such as an electric applianc...

Страница 9: ...unit towards you and then pull down 6 Check the installation Check to make sure that the tabs on mount ing bracket 2 are securely mounted to the tabs on mounting bracket 1 Check that the power cord is not pinched REMOVING THE UNIT Pull the bottom of the unit towards you and then lift NOTES When removing the unit use a firm stand Disconnect the power cord before removing the unit Cushions 2 units E...

Страница 10: ...nd slide the back cover to re move 2 Insert batteries Insert batteries with and as shown below 3 Close the back cover About the batteries The battery life is about 1 year Replace the batteries when the remote con trol becomes inoperative Incorrect usage of the batteries may cause battery fluid leakage and or damage Take caution of the following when handling When replacing the batteries replace bo...

Страница 11: ... the 4 tabs on the pre filter in the holes of the main unit 4 Fill in the usage start date on the replacement label affixed on the back of the front panel and then mount the front panel Use the date as a guide for the filter replacement period Back of front panel Replacement label Operate the remote control facing the main unit re ceiver The signal range is about 7m front Make sure there are no ob...

Страница 12: ...nit will return to the AUTO mode 10 minutes High fan level AUTO mode operation Pollen mode operation The unit will operate in High for 10 minutes then the unit will alternately operate between Median and High 10 minutes High fan level 20 minutes Median level 20 minutes High fan level For the first 30 seconds after the power plug is inserted into the wall outlet the unit will check the conditions o...

Страница 13: ...ours Cancel The remaining time is indi cated by the lamp as time passes The unit will stop operation when the timer is up Cluster ion select button AUTO cluster ion button The unit will switch between the Clean mode and Refresh mode automatically depending on the amount of pollution in the air detected by dust and odor sensor Clean button The unit will constantly operate in the Clean mode The Clea...

Страница 14: ... of 40 C or less Do not use volatile fluids Benzene paint thinner polishing powder etc may damage the unit surface Do not use detergents Detergent ingredients may damage the unit surface Do not get wet Never apply water on the unit ODOR SENSOR DUST SENSOR The sensitivity of the sensors will become unstable if the odor or dust sensor is dirty or blocked Remove dust on the surfaces of the sensor ope...

Страница 15: ...ge environment this odor may become strong in several months and the exhaust port may smell If dust or odors cannot be removed easily replace the filters Refer to page1 FOR UNDERSTANDING THE PRODUCT REPLACING THE FILTERS 1 See page 8 Installing the filters for the replacement method 2 After replacing the filters Be sure to press the Reset button on the remote control with the power plug inserted i...

Страница 16: ... cluster ions varies depending on humidity of room air but cluster ions are effective regardless of the noise level If the sound is irritating such as when sleeping etc use to keep this product away The discharged air smells The ozone generated by the cluster ion generator may have an odour However the density of ozone generated is very little and is harmless to the human body Furthermore the ozon...