FO-5700U
5 – 9
PIN
I/O
Name
Function
101
–
GND
Ground
102
O2M
XEXCS
Chip select (spare)
103
I
XCDCINT
Interrupt request signal from CODEC
104
I
XCDCDRQ
DMA request signal (CODEC)
105
O2M
XCDCCS
Chip select (CODEC)
106
O
XWR
System write output
107
O2M
FLBK4
Bank control 4
108
O2M
FLBK3
Bank control 3
109
O2M
FLBK2
Bank control 2
110
O2M
FLBK1
Bank control 1
111
IU
XFLBSY
Flash memory busy signal input
112
IU
FLSZ0
Input port
113
IU
FLSZ1
Input port
114
O2M
XFLSTD
Chip select (flash standard)
115
O2M
XFLOPT
Chip select (flash option)
116
IU
XCI
Input port
117
IU
XRHS
Input port
118
IU
XEXHS
Input port
119
TO
DPON
Output port
120
–
GND
Ground
121
TO
TXMUTE
Output port
122
IU
HSDTCT
Input port
123
TO
MPXC
Output port
124
TO
MPXB
Output port
125
TO
DPMUTE
Output port
126
IU
PCDTCT
Input port
127
TO
FAXPCSL
Output port
128
O2M
XD9001CS
Chip select (PC I/F D9001)
129
O2M
XD9001RW
Read signal to D9001 (PC I/F)
130
O2M
XD9001WR
Write signal to D9001 (PC I/F)
LZ9FJ59 (IC17) Terminal list
PIN
I/O
Name
Function
131
O2M
XD6004RD
Read signal to D6004 (PC I/F)
132
O2M
XD6004WR
Write signal to D6004 (PC I/F)
133
O2M
D6004ALE
Address strobe signal to D6004 (PC I/F)
134
–
GND
Ground
135
IO
AD7
PC I/F address/data input/output
136
IO
AD6
PC I/F address/data input/output
137
IO
AD5
PC I/F address/data input/output
138
IO
AD4
PC I/F address/data input/output
139
IO
AD3
PC I/F address/data input/output
140
IO
AD2
PC I/F address/data input/output
141
–
GND
Ground
142
–
VDD
Power supply
143
IS
CK16M
16MHz clock input
144
ID
TEST1
Test terminal
145
IO
AD1
PC I/F address/data input/output
146
IO
AD0
PC I/F address/data input/output
147
IU
XB4FRS
Input port
148
IU
XFRSNS
Input port
149
IU
XORGSNS
Input port
150
IU
XROLSNS
Input port
151
I
PRTSNS1
Input port
152
TO
CDCMSK
Output port
153
TO
PLG0ON
Plunger 0 control
154
TO
PLG1ON
Plunger 1 control
155
TO
LEDON
CIS LED light source control
156
IU
XEXINT0
Interrupt request signal from PC I/F
157
IU
XEXINT1
Interrupt request signal (spare)
158
I
PCIFSL
PC I/F select signal input
159
IO2M
IOP0
Input port (spare)
160
–
GND
Ground
I
: Input terminal (TTL level input)
IS
: Input terminal (TTL level schmitt input)
IU
: Input terminal (TTL level input, pull up resistor 250 K
Ω
building in)
ID
: Input terminal (TTL level input, pull down resistor 250 K
Ω
building in)
IO
: Input/output terminal (TTL level input, output electric current: I
OL
=4.0 mA)
IO2M : Input/output terminal (TTL level input, output electric current : I
OL
=2.0 mA)
O
: Output terminal (Output electric current: I
OL
=4.0 mA)
O2M : Output terminal (Output electric current: I
OL
=2.0 mA)
TO
: Try-state output terminal (Output electric current: I
OL
=4.0 mA)
VDD : Power supply
GND : Ground
Содержание FO-5700
Страница 83: ...FO 5700U LIU PWB parts layout 6 20 ...
Страница 86: ...FO 5700U Printer PWB parts layout Top side 6 23 ...
Страница 87: ...FO 5700U Printer PWB parts layout Bottom side 6 24 ...
Страница 89: ...FO 5700U Power supply PWB parts layout 6 26 ...
Страница 100: ...FO 5700U 6 37 Memory PWB parts layout Top side Memory PWB parts layout Bottom side ...