FO-5700U
5 – 2
(Continuing)
Classification
Code
Terminal No.
I/O
Name
Function
(TFP-100B)
Power
Vcc
13, 38, 63,
I
Power
Connect to the power supply.
73, 80, 88
Connect Vcc terminals to the power units of all systems.
If any open terminal is present, it will not operate
Vss
4,15,24,32,
I
Ground
Connect to the ground.
41,50,59,70,
Connect Vcc terminals to the power units of all systems.
81,82, 92
If any open terminal is present, it will not operate.
Clock
EXTAL
71
I
External clock
Connect to the quartz oscillator. Moreover, EXTAL terminal can
input the external clock.
Use the same frequency for the quartz oscillator, external clock
and system clock.
XTAL
72
I
Crystal
Connect the quartz oscillator. Connect the same frequency of the
system clock (CK).
To input external clock from EXTAL terminal, open EXTAL
terminal.
CK
69
O
System clock
Supply system clock to the peripheral device.
System control
RES
76
I
Reset
If this terminal is turned to the low level when NMI is at the high
level, it will be brought into the power-on state. If this terminal is
turned to the low level when NMI is at the low level, it will be
brought into the manual.reset state.
WDTOVF
75
O
Watch dog timer
It is overflow output signal from WDT.
overflow
BREQ
60
I
Bus right request
Select the low level to make the external device request the
release of bus right.
BACK
58
O
Bus right request
It indicates that the bus right is released to the external device.
acknowledge
When receiving BACK signal, the device which outputs BREQ
signal can know that bus right is obtained.
Operation
MD2~
79~77
I
Mode setting
The terminal determines the operation mode.
mode control
MD0
During operation, don’t vary any input value. The relationship
between MD2 thru MD0 and operation modes are shown in the
following list.
Interrupt
NMI
74
I
No-maskable interrupt
This is the interrupt request terminal which can not be masked.
Either leading edge or trailing edge is selected for receiving.
IRQ0~
65,66,67,68,
I
Interrupt request 0
This is the interrupt request terminal which can be masked.
IRQ7
97,98,99,100
thru 7
Either level input or edge input can be selected.
IRQOUT
61
O
Interrupt request
It indicates that a factor of interrupt occurs.
output in the slave
It indicates that interrupt occurs in the bus release mode.
mode
Address
A21~A0
45~42,40,39,
O
Address
Address is output.
37~33,31~25,
23~20
Data bus
AD15~
19~16,14,
I/O
Data bus
Bidirectional data bus of 16 bits
AD0
12~5,3~1
Multiplex is possible with the low-order 16 bits of the address.
DPH
64
I/O
High-order side data
Parity data corresponds to D15 thru D8.
bus parity
DPL
62
I/O
Low-order side data
Parity data corresponds to D7 thru D0.
bus parity
Relationship between MD2 thru MD0 and operation modes
MD2
MD1
MD0
Operation mode
Integrated ROM
Bus width of area 0
0
0
0
Invalid
8-bit size
0
0
1
MCU mode
16-bit size
0
1
0
Valid
—
0
1
1
(Reserved)
—
—
1
0
0
(Reserved)
—
—
1
0
1
(Reserved)
—
—
1
1
0
(Reserved)
—
—
1
1
1
(Reserved)
—
—
SH7021 (IC27) Terminal descriptions
Содержание FO-5700
Страница 83: ...FO 5700U LIU PWB parts layout 6 20 ...
Страница 86: ...FO 5700U Printer PWB parts layout Top side 6 23 ...
Страница 87: ...FO 5700U Printer PWB parts layout Bottom side 6 24 ...
Страница 89: ...FO 5700U Power supply PWB parts layout 6 26 ...
Страница 100: ...FO 5700U 6 37 Memory PWB parts layout Top side Memory PWB parts layout Bottom side ...