FO-5700U
2 – 6
19) Dial test mode
The mode is used to inspect whether dialing is accurate in two kinds of
dial modes . All data which can be dialed in this mode are automatically
called up in both PB mode and DP mode.
When this mode is activated, the following operations will be automat-
ically executed . Whether the dialed content is right or not is judged with
the external instrument which is connected to the line cable.
1
After shift to the FAX diagnosis mode, press RAPID 24.
(Also switch the display with the [ ] and [#] keys.)
2
Press the START key.
3
Turn on CML, and dial the following in the PB mode.
1, 2, 3, 4, 5, 6, 7, 8, 9, , 0, #
4
Turn off CML 500 mS alone.
5
Dial the following in the DP mode.
1, 5, 9, 0
6
After dialing, turn off CML.
This mode uses the ordinary auto dial. (Accordingly, the signal sending
time and minimum pause are all the same as ordinary.
The measurement result in this mode is completely all the same as in
the ordinary dial mode.
Moreover, the same process as above is also done in the dial test mode
which is executed in the product check mode.
20) Copy diag mode
In order to shorten the process time during production, this mode is
used to automatically switch the copy mode. Three menus are provided.
1.
1
Set up two documents. (In case of two documents or more,
there is no problem.
2
Press the START key.
3
Copy 1st document in the fine mode/density AUTO. (One sheet
is printed in the ordinary copy mode.)
4
Copy 2nd (subsequential) document in the intermediate tone
mode/density DARK. (In the ordinary copying mode, one sheet
is printed when the RESOLUTION key is pressed three times.)
When copy test is tried during production or is checked in two modes
(fine and intermediate tones), this mode is provided to reduce the trou-
blesome work which makes the operator stand aside to change the mode.
Accordingly, the fine and intermediate tones are merely switched, and
the mode is not switched to another mode. (Input of the image quality/
density key is invalid.)
2. Try the copy in the mode fixed at COPY REDUCE 95% and fine
mode/density AUTO. At this time, don’t change the soft key of
COPY REDUCE. (Input of the image quality/density key is invalid.)
3. Continuously try the above items 1 and 2.
21) Signal Send Mode2
The signals concerned with V.34 & V.8 are checked.
After this mode is activated, press the START key, and the signals will
be sent in the following sequence.
It can be used to check the modem.
[ 1] No signal
[ 2] 33600BPS
[ 3] 31200BPS
[ 4] 28800BPS
[ 5] 26400BPS
[ 6] 24000BPS
[ 7] 21600BPS
[ 8] 19200BPS
[ 9] 16800BPS
[10] 14400BPS
[11] 12000BPS
[12] 9600BPS
[13] 7200BPS
[14] 4800BPS
[15] 2400BPS
22) JBIG Test Mode
1
Enter the diagnostic mode.
2
Press the RAPID22 button. ("22: JBIG TEST MODE" appears.)
3
Press the START key to begin the JBIG test operation.
When both tests are completed normally, the buzzer sounds and "JBIG
TEST NORMAL END" appears at the same time.
If the decoding test terminates abnormally, the buzzer sounds and
"ERROR: JBIG DECODE" appears at the same time.
If the encoding test terminates abnormally, the buzzer sounds and
"ERROR: JBIG ENCODE" appears at the same time.
Содержание FO-5700
Страница 83: ...FO 5700U LIU PWB parts layout 6 20 ...
Страница 86: ...FO 5700U Printer PWB parts layout Top side 6 23 ...
Страница 87: ...FO 5700U Printer PWB parts layout Bottom side 6 24 ...
Страница 89: ...FO 5700U Power supply PWB parts layout 6 26 ...
Страница 100: ...FO 5700U 6 37 Memory PWB parts layout Top side Memory PWB parts layout Bottom side ...