Reset, Clock, and Power Controller
LH75400/01/10/11 (Preliminary) User’s Guide
9-18
7/15/03
9.3.2.13 External Interrupt Configuration Register
IntConfig is the External Interrupt Configuration Register. The active bits used in this reg-
ister are Read/Write.
This register configures the individual external interrupts to be either edge-sensitive or
level-sensitive and either active HIGH or active LOW. When reset, all bits are cleared and
configure the external interrupts to be active LOW-level sensitive. The corresponding
edge-trigger interrupt should be cleared before enabling the edge-trigger interrupt to
clear a false interrupt.
Table 9-30. IntConfig Register
BIT
31
30
29
28
27
26
25
24
23
22
21
20
19
18
17
16
FIELD
///
RESET
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
RW
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
BIT
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
0
FIELD
///
INT6
INT5
INT4
INT3
INT2
INT1
INT0
RESET
0
0
0
0
0
0
0
0
1
0
0
0
0
0
0
0
RW
R
R
RW
RW
RW
RW
RW
RW
RW
RW
RW
RW
RW
RW
RW
RW
ADDR
0xFF 0x80
Table 9-31. IntConfig Register Definitions
BITS
FIELD NAME
DESCRIPTION
31:16
///
Reserved
Writing to these bits has no effect. Reading returns 0.
15:14
///
Reserved
Read as 0, do not modify.
13:12
INT6
Configures External Interrupt INT6
00 = Configures INT6 to be a LOW-level trigger.
01 = Configures INT6 to be a HIGH-level trigger.
10 = Configures INT6 to be a falling-edge trigger.
11 = Configures INT6 to be a rising-edge trigger.
11:10
INT5
Configures External Interrupt INT5
00 = Configures INT5 to be a LOW-level trigger.
01 = Configures INT5 to be a HIGH-level trigger.
10 = Configures INT5 to be a falling-edge trigger.
11 = Configures INT5 to be a rising-edge trigger.
9:8
INT4
Configures External Interrupt INT4
00 = Configures INT4 to be a LOW-level trigger.
01 = Configures INT4 to be a HIGH-level trigger.
10 = Configures INT4 to be a falling-edge trigger.
11 = Configures INT4 to be a rising-edge trigger.
7:6
INT3
Configures External Interrupt INT3
00 = Configures INT3 to be a LOW-level trigger.
01 = Configures INT3 to be a HIGH-level trigger.
10 = Configures INT3 to be a falling-edge trigger.
11 = Configures INT3 to be a rising-edge trigger.