LC-60E77UN/LC-65E77UM/LC-C6077UN/LC-C6577UM
4 – 4
4. Removing of MAIN Unit, FPGA Unit, LCD Control Unit and POWER Unit.
1. Remove the 4 lock screws
and detach the MAIN Unit
.
2. Remove the 3 lock screws
, 2 lock screws
and 2 Panel Lug
and detach the MAIN PWB Angle
.
3. Remove the 4 lock screws
and detach the FPGA Unit
.
4. Remove the 4 lock screws
and detach the LCD Control Unit
.
5. Remove the 2 lock screws
and 4 lock screws
and detach the Control PWB Angle
.
6. Remove the 8 lock screws
and 1 hook
and detach the POWER Unit
.
7. Remove the 4 lock screws and detach the POWER PWB Angle
16
POWER Unit
18
POWER PWB Angle
2
MAIN Unit
6
MAIN PWB Angle
15
4
12
3
5 Panel Lug
5 Panel Lug
11
9
7
8
FPGA Unit
10
LCD Control Unit
13
Control
PWB Angle
4
1
14
17
LCD Panel Module Unit Ass'y
Connecting
Cord
(FFC2)
Connecting
Cord
(FFC1)