LC-60/70LE745U,C7450U,LE845U,C8470U,LE847U (1st Edition)
6 – 1
LC60LE745U
Service Manual
CHAPTER 6.
TROUBLESHOOTING TABLE
[1] Failure diagnosis by LED in front of cabinet
[2] LED flashing specification at the time of an error (Center icon LED used)
1. Display method
•
Since only the center icon LED can be used, slow flashing and fast flashing are combined.
•
Refer to Table 1.
•
The Start from the detail display. (No outline display)
•
After recovering from an error, if the same error cannot be generated again, refer to MONITOR ERR CAUSE on the process screen.
•
During version upgrade, the brightness of the flashing LED changes smoothly.
•
When completing version upgrade, the brightness of the LED changes in a staircase pattern.
2. LED flashing method
Error flashing
<Detail display example>
•
Flashing during Verup
•
Flashing when completing Verup
No
Yes
No
Yes
No
Yes
Is the Center Icon flashing?
START
Is the Center Icon lighting
When AC plug on?
Is the Backlight lighting?
Check "[2] LED flashing specification at the time of an error (Center icon LED used)".
Check Power-Unit and AC-cable.
Check "
LED Backlight does not turn on.".
Check "
Picture does not display.".
1600ms
300ms
100ms
400ms
400ms
1600ms
OFF
ON
Center icon
500ms
500ms
OFF
ON
Center icon
1000ms
1000ms
1000ms
1000ms
OFF
ON
Center icon
Содержание Aquos LC-60LE845U
Страница 8: ...LC 60 70LE745U C7450U LE845U C8470U LE847U 1st Edition 2 2 ...
Страница 70: ...LC 60 70LE745U C7450U LE845U C8470U LE847U 1st Edition 7 3 MEMO ...
Страница 74: ...LC 60 70LE745U C7450U LE845U C8470U LE847U 1st Edition 8 4 MENO ...
Страница 85: ...LC 60 70LE745U C7450U LE845U C8470U LE847U 1st Edition ...