21JF2-RU/GA/SA/SF/SS
2 – 1
21JF2-RU/GA/SA/SF/SS
Service Manual
CHAPTER 2.
IMPORTANT SERVICE NOTES
[1] IMPORTANT SERVICE NOTES
Maintenance and repair of this receiver should be done by qualified service personnel only.
1. SERVICE OF HIGH VOLTAGE SYSTEM AND PICTURE TUBE
When servicing the high voltage system, remove static charge from it by connecting a 10K ohm resistor in series with an insulated wire (such as a test
probe) between picture tube dag and 2nd anode lead. (AC line cord should be disconnected from AC outlet.)
1) Picture tube in this receiver employs integral implosion protection.
2) Replace with the same type number of picture tube for continued safety.
3) Do not lift picture tube by the neck.
4) Handle the picture tube only when wearing shatterproof goggles and after discharging the high voltage completely.
2. X-RAY
This receiver is designed so that any X-Ray radiation is kept to an absolute minimum. Since certain malfunctions or servicing may produce potentially
hazardous radiation with prolonged exposure at close range, the following precautions should be observed:
1) When repairing the circuit, please make sure do not increase the high voltage of the set to more than 30.0kV (at beam 0
µ
A).
2) To keep the set in a normal operation, please make sure it’s function at 26.5kV
±
0.5kV (at beam 1000
µ
A). The set has been factory - adjusted to
the above-mentioned high voltage.
*If there is a possibility that the high voltage fluctuates as a result of the repairs, never forget to check for such high voltage after the work.
3) Do not substitute a picture tube with unauthorizerd types and/or brands which may cause excessive X-ray radiation.
3. BEFORE RETURNING THE RECEIVER
Before returning the receiver to the user, perform the following safety checks.
1) Inspect all lead dress to make certain that leads are not pinched or that hardware is not lodged between the chassis and other metal parts in the
receiver.
2) Inspect all protective devices such as non-metal control knobs, insulating materials, cabinet backs, adjustment and compartment covers or
shields, isolation resistor-capacity networks, mechanical insulators etc.
Содержание 21JF2 Series
Страница 52: ...21JF2 RU GA SA SF SS 8 2 3 BLOCK DIAGRAM MAIN UNIT A C B D E F G H 1 2 3 4 5 6 7 8 9 10 ...
Страница 53: ...21JF2 RU GA SA SF SS 8 3 10 11 12 13 14 15 16 17 18 19 ...
Страница 57: ...21JF2 RU GA SA SF SS 11 2 10 11 12 13 14 15 16 17 18 19 ...
Страница 58: ...21JF2 RU GA SA SF SS 11 3 2 21JF2 GA 21JF2 SA 21JF2 SF A C B D E F G H 1 2 3 4 5 6 7 8 9 10 ...
Страница 59: ...21JF2 RU GA SA SF SS 11 4 10 11 12 13 14 15 16 17 18 19 ...
Страница 60: ...21JF2 RU GA SA SF SS 11 5 3 21JF2 SS A C B D E F G H 1 2 3 4 5 6 7 8 9 10 ...
Страница 61: ...21JF2 RU GA SA SF SS 11 6 10 11 12 13 14 15 16 17 18 19 ...
Страница 64: ...21JF2 RU GA SA SF SS 12 2 3 PWB A MAIN UNIT 1 MAIN UNIT Component Side A C B D E F G H 1 2 3 4 5 6 7 8 9 10 ...
Страница 65: ...21JF2 RU GA SA SF SS 12 3 10 11 12 13 14 15 16 17 18 19 ...
Страница 66: ...21JF2 RU GA SA SF SS 12 4 2 MAIN UNIT Chip Parts Side A C B D E F G H 1 2 3 4 5 6 7 8 9 10 ...
Страница 67: ...21JF2 RU GA SA SF SS 12 5 10 11 12 13 14 15 16 17 18 19 ...