background image

MULTI-HEAD PEX CRIMP TOOL KIT 

#865896

INSTRUCTION GUIDE

CA865869INSTv

3

 DISTRIBUTED BY  

RELIANCE WORLDWIDE CORPORATION

 

2727 

Paces Ferry Road SE, Building II, Suite 1800, 

Atlanta, GA 30339 | T +1 877 700 4242

ADJUSTMENT PROCEDURE

CONNECTION ASSEMBLY

WARRANTY

CHECK ALL CRIMPS WITH GO/NO-GO GAGE

GAGING PROCEDURE

Cut the tube so that a clean, straight end is provided. Slide the crimp 
ring over the tube end. Insert the fitting into the tubing until the 
shoulder of the fitting contacts the tubing end. Position the crimp ring 

1/8" to 1/4" (3.2 to 6.4 mm) from the cut end of the tubing.

Place the opened jaws of the PEX Crimp Tool around the crimp 
ring. Check to be sure that the crimp ring is still properly positioned. 
Compress the tool handles to complete the assembly. 

1.

Check tool calibration daily. It
is recommended that at least
the first and last crimps of the
day are tested.

2. Never exceed the specified

handle distance when
adjusting your crimp tool.
Premature wear will result.

3. Lubricate linkages on a regular

basis to maximize tool life.

When properly maintained and used 
as intended, the PEX Crimp Ring Tool 
is warranted against materials and 
manufacturing defects for a period  
of 1 year from date of purchase.  

This Warranty does not cover defects 

or damage arising from improper 
installation, lack of or improper 
maintenance, improper storage or 
handling, ordinary wear and tear, 
misuse, abuse or accident, 
or use with unauthorized tool or 
parts. Liability is limited to repair or 
replacement of tool or component 
parts which are determined defective 
as covered by this Warranty.

3/8", 1/2" AND 3/4" PEX INSERTS 

(TOOL WITHOUT DIE SET CRIMPS 1

"

)

1.

Determine proper size of tubing: 3/8", 1/2", 3/4" or 1"

2. If GO cavity fits over crimped ring and NO-GO does not, tool is

crimping properly.

3. If GO cavity does not fit then handle distance must be increased.

4.

If GO fits—check NO-GO. If NO-GO fits over crimped ring,
the ring is over-crimped, decrease handle distance. Recheck.

NOTE: Over-crimped and under-crimped rings must be removed from 
tubing. Crimp with a new copper ring.

1.

Close tool handles until pre-load is reached (this is the point at 
which jaws touch). Tool should not be completely closed.

2. Measure the distance between dots on the handle ends as shown.

8"– 8 3/4" is the correct distance. If the distance is not 8" – 8 3/4"
the tool must be adjusted.

3. To change the handle ends distance, remove the #6-32 eccentric 

lock screw with an Allen wrench and push up eccentric from
back. Rotate eccentric counter-clockwise to increase the handle 
distance and clockwise to decrease handle distance. Move
eccentric until hand distance is between 8" – 8 3/4". Push down
eccentric and re-install the #6-32 lock screw in the appropriate
hole which most closely yields the desired handle distance.

4.

Recheck the set distance after making three crimps. The distance
should be 8

"

 – 8 3/4" between the “dots” on the handles.

5. Check the crimps with the go/no-go gauge provided. If satisfactory 

crimps do not result, the tool is likely worn and should be replaced.

United States: Oetiker, Inc. | 6317 Euclid Street 
Marlette, Michigan 48453 | T +1 800 959 0398
[email protected]

www.oetiker.com

8"– 8 3/4"

HANDLE PRE-LOAD

“DOTS”

To insert/remove dies open tool fully 

and push up plunger pin from back 
side of tool.

TOOL MAINTENANCE

Eccentric

Lock 
Screw

Gage all crimps as shown.

CRIMPS CONFORM TO ASTM  F 1807

Отзывы: