background image

Model 2025-CP

TV CONTROL BOX

#8. INSULATED  

QUICK-DISCONNECT 

TERMINALS

 CP2025A HARDWARE KIT

 1.    (1)  2025-CP Control Box
 2.  (1)  Plug-in Transformer 

       Input: 120 VAC, 60 Hz 

              Output: 16 VDC, 140 ma
 3.   (2)  Insulated Ring Terminals
 4.   (2)  VB-1000 Voltage Blocks
 5.   (1)  2-Way Splitter
 6.   (4)  Twist-on Type F-Connectors
 7.   (4)  #6 5/8” Screws
 8.  (4)  Isulated Quick-Disconnect    

            

  Terminals

 9.  (1)  5’ 18 GA Insulated Wire
 10.  (4)  1” Velcro Strips 

 

 

                      

WARNING!

To prevent FIRE or SHOCK HAZARD, avoid exposure 

of control panel to moisture.

NOTE:

 Please read all instructions 

before

 beginning installation!

 #6. TWIST-ON

F-CONNECTOR

#1. 2025-CP 

CONTROL BOX

#3. INSULATED RING 

TERMINALS 

#2. PLUG-IN  

TRANSFORMER

#10. VELCRO STRIPS

TOOLS NEEDED

#2 Phillips screwdriver
7/16” wrench
Crimping tool
Medium slot screwdriver
Wire stripper

#9. 18 GA INSULATED WIRE

#7. 5/8” SCREWS

#4. VB-1000 VOLTAGE BLOCK

#5. SP-1002 TWO WAY 

SPLITTER

REQUIRED ITEMS NOT INCLUDED 

IN THIS KIT

FOR TWO OR MORE TV SET SYSTEMS

• 

(1) PS-9381 Power Supply

NOTE: VB-1000 & SP-1002 are Winegard 
model numbers. 

Pull back braid over jacket.  

Make sure no braid touches 

center conductor. Figure B.

Screw the F-connector onto 

the cable jacket until the  cen-

ter conductor extends 

1/8” past end of connector. 

Figure C.

To install the F-connectors, 

strip the ends of the RG-59 

cable as shown in Figure A.  

(Note the ends of the original  

30’ cable have been factory  

pre-stripped for convenience.)

Figure A

Figure B

Minimum Bending Radius:

 3” for RG-59. Tighter bends 

will cause shorts and change impedance.

Pulling Tension:

 75 pounds maximum. Leave no tension 

on cable after it is installed.

Staples or Clamps:

 The use of flat staples with coax ca-

ble is damaging to the cable. Only round headed staples 

can be used. Any clamps or securing devices used with 

coax should grip the cable evenly about the circumference 

without crushing the cable.

Exposure to High Heat:

 Maximum temperature limit 

is 176° F (80° C). Keep cable away from heating vents, 

engine compartments and engine exhaust pipes.

Crushing:

 Coax should not be installed in a manner that 

would allow it to be crushed. It should not be stuffed or 

wedged into areas where the cable could be pinched by 
the flexing of the boat hull or cabin

.

Exposure to Moisture:

 The cable jacket will withstand 

most outdoor environments. However, connections and 

splices must be sealed against water entry.

HOW TO INSTALL F-CONNECTORS ON CABLE 

for female or extend for male

 

RECOMMENDATIONS FOR INSTALLING CABLE

Figure C

Printed in U.S.A.  © 2010 Shakespeare Company

2451257 Rev.1 8/10

Shakespeare Electronic Products Group                                   

6111 Shakespeare Rd., Columbia, SC 29223

Отзывы: