KapitelbezeichnungKapitelbezeichnung
X.X Unterpunkt
LCD 240-2VSLCD 240-2VPLCD 240-2HSLCD 240-2HSCLCD 240-2HPLCD 240-2HPC
User manual LCD 240-2xx
Страница 1: ...Kapitelbezeichnung Kapitelbezeichnung X X Unterpunkt LCD 240 2VS LCD 240 2VP LCD 240 2HS LCD 240 2HSC LCD 240 2HP LCD 240 2HPC User manual LCD 240 2xx...
Страница 2: ...ntact Phone 49 7571 722 51 Fax 49 7571 722 99 Copyright Duplication copy print microfilm or any other form as well as electronic spreading of this document is only permitted after formal writting cons...
Страница 3: ...ies 9 9 Tecnical information 10 9 1 Fuctional specifications 10 9 2 Display module specifications 10 9 3 Electrical connections 11 9 4 Configuration 11 10 Other devices wired in parallel 12 11 VEBUS A...
Страница 4: ...eful infor mation associated with certain floor s in addition to a regular car position indication 2 Display items symbols and fields Display is divided to four sub areas Names of these fields are as...
Страница 5: ...symbol number 1 is used for fire alarm 2 for over weight and 3 for service Own symbols can be edited and downloaded by means of LCD240 2xx Configurator software When any of the 4 symbols is displayed...
Страница 6: ...ramming mode is off the pin connector is active Emergency info picture parameter is used for se lecting the picture to be shown in the center of the display when power failure occurs There are three p...
Страница 7: ...standard display mode Setup Menu Input coding BIN GRAY Logo graphics OFF ON Programming PROG OFF ON Power Failure Polarity PF POLAR 0 1 Arrow input selection EXT AUTO Emergency info picture EMER INFO...
Страница 8: ...8 Assembly dimension LCD 240 2xx 7 Assembly dimension 172 137 0 1 147 0 1 120 57 63 53 0 1 59 0 1 43 0 1 113 63 37 2 3 Schwei bolzen M3 x 8 Schwei bolzen M3 x 10...
Страница 9: ...pictures automatic arrow programmable Gong LCD 240 2HS Basic version with VEBUS interface X X X X LCD 240 2HSC Extended version with VEBUS inter face X X X X X X LCD 240 2HP Basic version with parall...
Страница 10: ...mark consists of one or two letters or numbers 0 9 A Z minus sign Optional presentation of time and date Optional presentation of floor associated bitmaps of size 160 x 32 pixels capacity is 12 bitma...
Страница 11: ...rgency light documentation Control interface J2 Internal pull down or pull up resistors depending on jumper settings Jumpers are set to match control signal polarity Two jumpers to individually set po...
Страница 12: ...2 SM84 DMD are wired in parallel to the LCD 240 an uncoupling PCB has to be inserted into the signal lines common anode SYN42 SM84 DMD LCD 240 2 HP 2 HPC 2 VP or VEBUS A1 GND uncoupling PCB UB signal...
Страница 13: ...13 Other devices wired in parallel common cathode SYN42 SM84 DMD LCD 240 2 HP 2 HPC 2 VP or VEBUS A1 GND uncoupling PCB UB signal lines floors direction...
Страница 14: ...onverter card for different bus interfaces It is intended for lift appli cations It converts typical binary parallel control to RS 485 compatible serial control 10 2 Features Intended for lift applica...
Страница 15: ...ystem block diagram VEBUS A1 Parallel to serial converter 11 3 System block diagram LCD 240 4 I 3 I 3 I 3 I 3 I 3 Kabine Schacht Spannungsversorgung BUS Dual Gray Spannungsversorgung VEBUS A1 Aufzugss...
Страница 16: ...onnection 11 4 connection OUTPUT 55 65 85 95 Gnd V out B A Adr 0 V in Gnd Adr 1 Adr 2 Adr 3 Adr 4 Adr 5 Fahrt Sondertext 1 Sondertext 2 Sondertext 3 Sondertext 4 Gong auf Gong ab Pfeil auf Pfeil ab PA...
Страница 17: ...to match control signal polarity optional Pull down up resistance 10 k Input voltage range 0 30 VDC Power supply input Logic 0 0 1 VDC Logic 1 10 30 VDC Symbol control inputs 4 inputs for the symbol...
Страница 18: ...er J5 should be set tomatch the input signal polarity When changing jumper position first dis connect the device frompower supply then change the jumper position and after that connect the de vice bac...
Страница 19: ...19 Memo...