Product Version 1.0 | Revision A | Released 2022-4-21
Factory Defaults are as follows:
•
DMX address = 1
•
Dimming curve = Gamma Corrected
•
DMX mode/personality = Default mode (6 channel
CTC)
•
Startup mode = DMX
•
Screen saver = Off
•
Flip screen = Off
•
Fan mode = Standard
•
Led frequency = Dimming optimized
•
Master slave = Disabled
•
White calibrated = On
•
RDM device label set to = Fixture type name
•
Internal programs = Cleared
PLEASE NOTE! REMOTE DEVICE MANAGEMENT (RDM) REQUIRES A CORRECTLY INSTALLED AND TERMINATED
DMX CABLE.
When setting addresses through RDM and using USB dongles, it may be necessary to disable “USB selective sus
-
pend”
to ensure a proper voltage to the DMX link. If any lag or trouble occurs when addressing, decrease the cable
length range to <12 m. and only address one fixture at a time.
Figure 10: POI Spanner
LED INDICATOR BEHAVIOUR
The fixture displays the status of connections, setting and errors through the LED indicator. It can have different colors
and three possible stages: static, flashing, or off.
•
Solid Orange: Fixture is starting up.
•
Blinking Orange - Green: Fixture is resetting its functions.
•
Blinking Green: Reset has completed, no errors and no wireless or wired DMX connection.
•
Solid Green: Wireless and / or wired DMX connected.
•
Blinking Green - Orange - Red: Fixture is resetting and error(s) has occurred during reset.
•
Blinking Green - Red: Reset has completed but error(s) occurred during reset.
•
Solid Red (3 seconds): Hall sensor is activated. When activated for longer than 3 seconds, wireless DMX connec
-
tion is logged off.
•
Off: fixture is off or LED indicator is set to auto-dimming (set via RDM).
Once configuration is complete, temporary power and data can be disconnected.
In POI fixtures with wireless, it is necessary to pair the fix
-
ture with a new transmitter (by default, the fixture is linked
to the SGM factory transmitter during the testing and QA
process).
In order to do so, make sure the fixture is powered on be
-
fore taking the following steps:
STEP 1: Using a SGM magnetic spanner tool, place the mag
-
net close to the LED indicator, and wait for 3 seconds. The
LED indicator will blink orange for 1-2 seconds, before
switching to static green again. The fixture can now be
paired to a new transmitter.
STEP 2: Select “connect” or “link” on a wireless DMX trans
-
mitter. The transmitter and the internal SGM receiver
should now be linked together.
Repeat the process to link the fixture to another transmit
-
ter.
To disconnect the fixture from the currently paired wireless transmitter, hold the magnet for 3 seconds over the LED
indicator. The LED indicator will blink orange for 1-2 seconds, switching later to green again. The fixture is now logged
off.
WIRELESS DATA CONNECTION