background image

Sous réserve de modifications techniques !

13b rue Saint-Exupéry - ZA de l’Aérodrome - CS20152 - FR-67503 HAGUENAU CEDEX   www.sewosy.com  

Tél. +33 (0)3 90 59 02 20    Fax + 33 (0)3 90 59 02 19 

KR1000-M

ST_KR1000-M_A_170905

NOTICE DE MISE EN OEUVRE

CARACTÉRISTIQUES TECHNIQUES

 h x l x p

                   

122,50 x 78,50

x 22,50 mm

0,7 kg

12/24V

 AC/DC 110 mA

sortie

relais

= 2

30V DC - 2 A

125V AC - 0, 5 A

entrée 

bouton poussoir

 

= 2

1010

Relais 1 = 1000

Relais 2 = 10

65*

KR1000-M

13,56 MHz

(MIFARE)

3 modes de fonctionnement

 

:

 LECTEUR DE PROXIMITÉ

 LECTEUR DE PROXIMITÉ ou CODE

 LECTEUR DE PROXIMITÉ + CODE

 

   

ATTENTION :

 

      

dans ce cas, tous les utilisateurs doivent avoir 1 CODE et 1 BADGE DE PROXIMITE

0 - 99 s

-10+60°C

DIMENSIONS

*IP 65 : Protection contre les poussières, pas de dépôts nuisibles. Protection contre les jets d’eau à la lance de toutes directions

 ATTENTION : Veuillez respecter la polarité et la tension d’alimentation 12/24V AC/DC !

Lire attentivement cette notice avant mise en service et utilisation.
Utiliser ce matériel pour une application adaptée. Le fabricant n’est pas responsable des dommages éventuels causés par 

une utilisation contraire aux dispositions de sécurité.
Le montage, la maintenance et les réparations doivent être réalisés par un personnel spécialisé et autorisé.
La mise en oeuvre est très simple, mais une manipulation correcte et un entretien approprié sont des conditions  essentielles

 pour garantir un fonctionnement parfait.

1/24

Содержание KR1000-M

Страница 1: ...ivent avoir 1 CODE et 1 BADGE DE PROXIMITE 0 99 s 10 60 C DIMENSIONS IP 65 Protection contre les poussi res pas de d p ts nuisibles Protection contre les jets d eau la lance de toutes directions ATTEN...

Страница 2: ...o lectrique d autoprotection Pour l activer se r f rer la page 8 24 Autoprotection BP 1 Bouton poussoir Relais 1 BP 2 Bouton poussoir Relais 2 CM Contact Magn tique Sonnette Voir fonction sonnette en...

Страница 3: ...n option exemple 12 24V AC DC RACCORDEMENT D UNE VENTOUSE LECTROMAGN TIQUE VERROUILLAGE RUPTURE 12 24 V DC C NC NO DC en option exemple 12 24V AC DC EXEMPLES DE CONFIGURATIONS C NO C NO C NO GND BP1 G...

Страница 4: ...le code ma tre ou passer la carte ma tre 1 X code ma tre d origine 1234 BIP long LED verte fixe Entrer 7 LED verte fixe Entrer BIP long LED verte clignotante Passer la carte 1 X BIP long LED verte fix...

Страница 5: ...trer LED bleue fixe RELAIS 2 de 00 09 utilisateurs CARTE OU CODE Entrer 2 X le code ma tre ou passer la carte ma tre 1 X code ma tre d origine 1234 BIP long LED verte fixe Entrer 4 LED verte clignotan...

Страница 6: ...sition 2 digits obligatoires de 00 09 LED rouge fixe Entrer BIP long LED verte fixe Entrer LED bleue fixe Supprimer tous les utilisateurs Tous les codes et les cartes utilisateurs sont supprim s Entre...

Страница 7: ...2 de 01 99 secondes Entrer 2 X le code ma tre ou passer la carte ma tre 1 X code ma tre d origine 1234 BIP long LED verte fixe Entrer 5 LED verte clignotante Entrer la valeur 2 digits obligatoires de...

Страница 8: ...artes et codes programm s ne sont plus fonctionnels sur le relais 2 Cette fonction permet le remplacement d une sonnette Pour sonner appuyer sur la touche ACTIVER Entrer 2 X le code ma tre ou passer l...

Страница 9: ...have 1 PIN CODE and 1 PROXIMITY CARD 0 99 s 10 60 C DIMENSIONS IP 65 Protection against intrusion of dust Protection against low pressure water jets from any direction ATTENTION Make sure to observe c...

Страница 10: ...nti tamper photocell To activate the function please refer to page 16 Anti tamper function BP 1 Exit Button Relay 1 BP 2 Exit Button Relay 2 CM Door Magnet Bell Please refer to Bell function on page 1...

Страница 11: ...C NO optional example 12 24V AC DC CONNECTION OF AN EM LOCK FAIL SAFE LOCKING 12 24 V DC C NC NO DC optional example 12 24V AC DC EXAMPLES FOR TYPICAL WIRING CONFIGURATIONS C NO C NO C NO GND BP1 GND...

Страница 12: ...nter the master code 2 X or swipe the master card 1 X Default code is 1234 long BEEP LED will turn green Enter 7 LED will turn green Enter long BEEP LED will flash green Swipe the card 1 X long BEEP L...

Страница 13: ...AY 2 from 00 to 09 users CARD OR CODE Enter the master code 2 X or swipe the master card 1 X Default code is 1234 long BEEP LED will turn green Enter 4 LED will flash green Enter the position from 00...

Страница 14: ...osition 2 mandatory digits from 00 to 09 LED will turn red Enter long BEEP LED will turn green Enter LED will turn blue Delete all users All user codes and cards will be removed Enter the master code...

Страница 15: ...2 from 01 to 99 seconds Enter the master code 2 X or swipe the master card 1 X Default code is 1234 long BEEP LED will turn green Enter 5 LED will flash green Enter the 2 digits value mandatory from 0...

Страница 16: ...function is activated the programmed cards and codes will no longer be functional on relay 2 This function could be used as a bell Press on key to ring the bell to ENABLE the bell function Enter the...

Страница 17: ...ll m ssen alle Benutzer 1 CODE und 1 BER HRUNGSLOSE KARTE besitzen ABMESSUNGEN IP 65 staubdicht Schutz gegen Strahlwasser ACHTUNG Anschlu polarit t und H he der Betriebsspannung beachten 12 24V AC DC...

Страница 18: ...andsanzeige Falls jemand die T r ge ffnet hat und eingetreten ist und diese danach wieder geschlossen ist detektiert das Ger t automatisch die T rposition und verriegelt die T r Dies erfolgt obgleich...

Страница 19: ...DC C NO NO C NO optional Beispiel 12 24V AC DC RUHESTROM VERRIEGELUNG MIT HAFTMAGNET ANSCHLU 12 24 V DC C NC NO DC optional Beispiel 12 24V AC DC BEISPIELANSCHLU KONFIGURATIONEN C NO C NO C NO GND BP1...

Страница 20: ...Masterkarte an den Leser halten Ursprungsmastercode 1234 langer PIEP Ton gr ne LED leuchtet 7 eingeben gr ne LED leuchtet eingeben langer PIEP Ton gr ne LED blinkt 1 X Karte an den Leser halten lange...

Страница 21: ...rsprungsmastercode 1234 langer PIEP Ton gr ne LED leuchtet 4 eingeben gr ne LED blinkt Position eingeben von 00 bis 09 zweistellige Ziffernanzahl obligatorisch gr ne LED leuchtet Falls KARTE 1 X arte...

Страница 22: ...Ziffernanzahl obligatorisch rote LED leuchtet eingeben langer PIEP Ton gr ne LED leuchtet eingeben blaue LED leuchtet Alle Benutzer l schen Alle Codes und Benutzerkarten werden gel scht 2 X Mastercode...

Страница 23: ...01 bis 99 Sekunden 2 X Mastercode eingeben oder 1 X Masterkarte an den Leser halten Ursprungsmastercode 1234 langer PIEP Ton gr ne LED leuchtet 5 eingeben gr ne LED blinkt Zeit Wert eingeben von 01 b...

Страница 24: ...ert so sind die programmierten Karten und Codes auf dem Relais 2 nicht mehr funktionsf hig Diese Funktion kann die T rklingel ersetzen Bet tigen des Klingeltasters auf Taste dr cken AKTIVIEREN 2 X Mas...

Отзывы: