Steering Gear Alarm System 

AL-101 

 

Maunual 

 
 

 

 
 
 

Содержание AL-101

Страница 1: ...1 Steering Gear Alarm System AL 101 Maunual ...

Страница 2: ...0 Dip Switch factory default Chapter 1 Operation ECR FWD AFT VDR Description keypad Description lamp Chapter 2 Dimension of AL101 series ECR FWD AFT VDR Chapter 3 Input Output signal terminal of AL101 ECR FWD AFT VDR Chapter 4 Test flow of AL101 ...

Страница 3: ...mode Full Half run independently Switch ON OFF Default 1 Operation Mode Test Mode ON 2 DC ON lamp blink Red Green DC ON lamp ON Red ON 3 Full Relay output Mode Half relay output Mode ON 4 NC NC 5 NC NC 6 Firmware download Normal mode OFF Switch ON OFF Default 1 Operation Mode Test Mode ON 2 Full Relay output Mode Half relay output Mode ON 3 NC NC 4 NC NC 5 NC NC 6 Firmware download Normal mode ON ...

Страница 4: ...4 AL101 Steering Gear Alarm System Chapter 1 ECR FWD AFT VDR Operation ...

Страница 5: ...experiences in control system Big square dial keypad for easy access to function button Self test feed back system internal utilizing NMEA0183 protocol available with AL101 VDR unit DIMMER Key available to adjust L E D brightness 5 step Permanent and durable L E D implement Low current power and high brightness L E D built in back light Monitoring system optimization on comfortable display Monitor...

Страница 6: ...on CAUTION ECR to FWD are the main line RxTx unit meaning wiring MUST be firstly from ECR to FWD then to either AFT to VDR or vice versa or anyone If FWD to AFT data line is broken then ECR to FWD will still be operational ...

Страница 7: ...7 Frontal Face AL101 ECR ...

Страница 8: ...8 AL101 FWD ...

Страница 9: ...9 AL101 AFT ...

Страница 10: ...10 AL101 VDR ...

Страница 11: ...zzer sound CAUTION If setting Dip Switch 2 setting done ON relay output will be working full mode Meanwhile if setting Dip switch 2 OFF relay output will be working half mode 2 RESET Key This key able to re boot to all lamp s activation and deactivation Press this key then press SILENCE Key again to maintain to each lamp s activation and deactivation Or check buzzer sound activation ...

Страница 12: ...on or deactivation This key check to LAMP itself working If on pressing this key both of activation and deactivation lamp ON at once Then if release this key the deactivation lamp will be OFF 4 DIMMER Key This key able to adjust to LAMP brightness Brightness has total 5 steps ...

Страница 13: ...put signal 2 second later LAMP activate 4 PUMP LOW OIL LEVEL LAMP Input signal 3 second later LAMP activate 5 DC ON LAMP Depend on input signal LAMP will be activate to RED or GREEN Please see the chapter 3 Input output signal terminal CAUTION Except above FU FAIL PUMP HYDR LOCK PHASE FAIL PUMP LOW OIL LEVEL these 4 kind LAMP the other LAMP will be activate once it has input signal ...

Страница 14: ...14 AL101 Steering Gear Alarm System Chapter 2 ECR FWD AFT Dimension ...

Страница 15: ...15 ECR FWD AFT ...

Страница 16: ...16 VDR ...

Страница 17: ...17 AL101 Steering Gear Alarm System Chapter 3 ECR FWD AFT VDR Input output signal terminal ...

Страница 18: ...18 ECR input output signal terminal ...

Страница 19: ...19 FWD input output signal terminal ...

Страница 20: ...20 AFT input output signal terminal ...

Страница 21: ...21 VDR output signal terminal ...

Страница 22: ...22 AL101 Steering Gear Alarm System Chapter 4 Test flow ...

Страница 23: ...alarm activated Step 9 check output signal to other equipment at ECR panel when alarm activated AUTOPILOT FAIL Step 1 Close AUTOPILOT FAIL contact at the FWD panel input Step 2 Autopilot fail indicator Red light is blinking for all the panels Step 3 Buzzer sound Step 4 Press the Silence button the autopilot fail indicator light is steady in Red and Buzzer is off Step 5 Press the alarm reset button...

Страница 24: ... sound again and indicator is blinking again Step 6 Repeat Step 4 Step 7 Stop supply 24V DC to the terminal input the power 1 fail indicator is still on Step 8 Press alarm reset button again the alarm indicator light off Step 9 Check out signal to other equipment at ECR panel when alarm activated All the other alarm testing has the same testing procedure as POWER 1 FAIL testing Procedure TIME DELA...

Страница 25: ...WD AFT alarm panel relay Signal output ECR 알람 패널 릴레이 신호 출력 4 7 Testing for signals output to VDR Every indicator light will have a respect 24V DC output at VDR option or data output for NMEA protocol option ...

Страница 26: ...age caused by operator Any kinds of Mal function Defection caused by using spare part from Non Authorized Distributor or Agent Any kinds of Mal function Defection caused by not following Warnings or Cautions mentioned on this manual Any kinds of Mal function Defection caused by Force Majeur like Fire Flood Without presentation of this Warrantee Certification 3 Other Any kinds of Warrantee Certific...