21
3 Operation
3.2.7
Settings
You can change the device settings and access information
about the device under
Settings
in the menu
(see
3.2.8
Starting/stopping/saving a measurement
Depending on the application, measurements will have to be
saved or started and then stopped.
Application
Measurement
start/stop
save
Inspection above
ground
×
Measuring in bar holes
×
House
×
Gas measuring
×
Difference between starting/stopping and saving
Selecting
Start measurement
followed by
Stop measurement
saves a measurement plot.
Selecting
Save measurement
saves an individual measurement,
the current one.
Note:
Measurements cannot be cancelled. The only way to cancel a
measurement is to stop it.
Up to 80 measurements can be saved.
The measured values can be saved with or without a comment.
Comment entries are saved automatically (ring memory with
max. 10 entries).
Once the first comment has been entered, the
Open
stored comments
function will become available.