22
7 Menu
Note:
You can access the
Aquaphon mode directly by
connecting a suitable microphone to the disabled
device (power OFF).
CAUTION!
Do not use the headphones with high volume. Au
-
diologists warn that the exposure to persistent or
sustained noise may result in hearing defects.
Set the volume to an appropriate level.
z
Switch off the headphones when you suspect that
z
interfering noise may occur (pedestrians, cars,
etc.).
Switch off the headphones before moving the
z
microphone.
Bear in mind that your perception capability is
z
reduced.
7.2.1.1 Display
The display contains the following components:
Measured value (sound level at microphone)
Set sensitivity
Headphones volume
Filter settings
Detected microphone type
sensitivity
correlator