21
7 Menu
Note:
Certain menu items are not available in the standard
version. If you select an item which is not available,
an appropriate message is indicated. If you want to
upgrade from the standard version to the profes-
sional version, a registration code is needed.
7.2
Listen
Use the Listen function to set the sound level of both channels.
Select the channel which you want to change with the arrow
z
keys.
You can then change the sound level of he selected channel
z
using the arrow keys or Rotary regulator.
If you select
z
„Channel 1“, you will hear channel 1 on both ears
(mono mode). The same applies to „Channel 2“. If you select
„Channel 1 and 2“, you will hear both channels at the same
time (stereo mode).
7.2.1
AQUAPHON
Use the “Aquaphon” function to enable the integrated feature
for searching leaks. This feature can be compared to that of the
Sewerin
AQUAPHON A 100 / AF 100 device. These devices, how
-
ever, are provided with a considerably wider range of functions.
You can use the microphones of this system.
The maximum measured value can be measured in the vicinity
of the leak.
Select the menu option Correlator to return to the correlator
mode.
To switch off the device:
pull the microphone connector from the socket (otherwise the
–
device is switched on again and again)
enable the Correlator menu item (this permits to save the modi
-
–
fied settings for sensitivity and sound volume)
press the ON/OFF button.
–