Operating Instructions – MOVITRAC® LTP
33
7
SEW electronics service
Operation and Service
7.3
SEW electronics service
Send in for repair
Please contact the
SEW-EURODRIVE electronics service if a fault cannot be
rectified
.
Please provide the following information when sending the unit in for repair:
• Serial number (
→
nameplate)
• Unit designation
• Brief description of the application (application, control via terminals or serial)
• Connected components (motor, etc.)
• Nature of the error
• Accompanying circumstances
• Your own presumption of what has happened
• Any unusual events preceding the problem, etc.
"SC-trP"
Communication loss trip
•
Check communication link between drive and
external devices.
•
Make sure each drive in the network has its
unique address.
"P-LOSS"
Input phase loss trip
Drive intended for use with a 3-phase supply has
lost one input phase.
"Ph-1b"
Phase imbalance
•
Mains incoming supply voltage has an imbal-
ance of >3 % for over 30 seconds.
•
Check incoming supply and fuses.
"dAtA-F"
Internal memory fault
•
Parameters not saved, defaults reloaded.
•
Try again. If problem reoccurs, contact SEW-
EURODRIVE Service.
"At-FO1"
Autotune failed
•
Measured motor stator resistance varies
between phases.
•
Ensure the motor is connected correctly and
fault-free.
•
Check the windings for correct resistance and
balance.
"At-FO2"
•
Measured motor stator resistance is too large.
•
Ensure the motor is connected correctly and
fault-free.
•
Check that the power rating corresponds to the
power rating of the connected drive.
"At-FO3"
•
Measured motor inductance is too low.
•
Ensure the motor is connected correctly and
fault-free.
"At-FO4"
•
Measured motor inductance is too high.
•
Ensure the motor is connected correctly and
fault-free.
•
Check that the power rating corresponds to the
power rating of the connected drive.
"At-FO5"
•
Measured motor parameters are not conver-
gent.
•
Ensure the motor is connected correctly and
fault-free.
•
Check that the power rating corresponds to the
power rating of the connected drive.
"SPIn-F"
Spin start failed
Spin start function failed to detect the motor speed.
Trip message
Explanation
Solution
0
0
I
Содержание MOVITRAC LTP series
Страница 2: ...SEW EURODRIVE Driving the world...
Страница 76: ......
Страница 77: ......
Страница 78: ......
Страница 79: ...SEW EURODRIVE Driving the world...