110
Operating Instructions – MOVIGEAR® SNI-B
6
Disabling DynaStop
®
for startup purposes
Startup
6.6
Disabling DynaStop
®
for startup purposes
6.6.1
Important notes on disabling DynaStop
®
6.6.2
Steps for disabling DynaStop
®
1. Observe chapter "Startup notes"!
2. It is essential that you observe chapter "Important notes on disabling DynaStop
®
".
3. Disconnect all components from the voltage supply and use an external disconnect-
ing device to avoid unintentional re-connection.
4. Completely remove the MOVIGEAR
®
electronics cover.
5. The DynaStop
®
function is now disabled and the plant/machine can be moved
mechanically observing the notes in chapter "Important notes on deactivating
DynaStop
®
".
WARNING
Removing the MOVIGEAR
®
electronics cover will disable DynaStop
®
.
Severe or fatal injuries.
• If it is not permitted to deactivate the system, additional measures are required (e.g.
mechanical stake-out)
WARNING
Electric shock due to regenerative energy when moving the system or machine.
Severe or fatal injuries.
• Never touch the MOVIGEAR
®
wiring space with wiring board and plug connector.
• If you cannot rule out that the wiring space is touched, provide for suitable
protection covers.
NOTICE
Damage to the plug connector due to regenerative energy when moving the system
or machine.
Potential damage to property.
• To disable DynaStop
®
, you have to remove the MOVIGEAR
®
electronics cover
completely to prevent damage to the plug connector (destroyed contacts).
INFORMATION
For more information about the DynaStop
®
function, refer to chapters "Operation" and
"Technical data and dimension sheets".