Setting for CFC/servo mode
Startup (MDR60A0150/0370/0750 and MDR61B1600/2500)
5.6
Setting for CFC/servo mode
If you use CFC mode, you have to make the corresponding selection during startup. The
following section illustrates the selection and the further procedure depending on the
MOVITOOLS
®
MotionStudio version.
• Select operating mode CFC "current-controlled with feedback".
•
Example A (version 5.7 with ServicePack 1):
Activate the checkbox "Unit is in DC
link connection...".
•
Example B (version 5.7 without ServicePack 1)
you additionally have to halve the
gain of the current controller (Kp I controller).
– Press <Shift> + Next> to confirm your selection.
– Change the setting Kp I controller setting to 50% of the suggested value.
MOVITOOLS
®
MotionStudio
Example A: Version 5.7 with ServicePack 1
(In preparation)
Example B: Version 5.7 without service pack
(latest version)
INFORMATION
The following unit combinations do not allow the operation of synchronous servomo-
tors with MOVIDRIVE
®
:
• MOVIDRIVE
®
MDR61B regenerative power supply unit size 7 in DC link connec-
tion with MOVIDRIVE
®
MDX61B inverters size 0 – 6
• MOVIDRIVE
®
MDX61B inverters size 7 in connection type A or B with
MOVIDRIVE
®
MDX61B inverters size 0 – 6