5
Electrical installation
Connection via hybrid cable
Operating Instructions – MOVITRANS
®
TPM12B Mobile Converter, System Frequency A – 25 kHz
27
5.4.3
Connector assignment X11
The following table shows the pin assignment of X11:
Pin assignment Designation
Function
X11:A1 (+U
z
)
500 V
DC 500 V output voltage
X11:A2 (–U
z
)
0V500
Reference potential for the DC 500 V output
voltage
X11:B1, B5
PA
Equipotential bonding for line and shield
X11:B2
n.c.
Not connected
X11:B3
Enable mode
Digital input enable mode (for DC 500 V output
voltage only):
"0" signal = delayed enable (ramp)
"1" signal = instantaneous enable
X11:B4
0V24
Reference potential for DC 24 V binary signals
X11:B6
500 V OK
Digital output 500V OK, "1" signal, if DC 500 V
output voltage is present.
X11:B7
Enable
Digital input enable (for DC 500 V output voltage
only):
"0" signal = DC 0 V output voltage
"1" signal = DC 500 V output voltage
X11:B8
24 V
DC 24 V voltage output (max. 2 A)
The pin assignment "Enable" and "Enable mode" only affect the DC 500 V output
voltage. The pin assignment "DC 24 V voltage output" remains unaffected.
5.5
Connection via hybrid cable
5.5.1
Prefabricated hybrid cable
SEW-EURODRIVE offers a prefabricated hybrid cable for connection to the plug con-
nector (part no. 11715073). All leads are enclosed in one jacket.
One cable end is fitted with a plug connector for connection to the TPM12B mobile
converter. The other cable end is open and fitted with wire end sleeves. The cables
are available in half-meter lengths from 1 m to 7.5 m.
1520575243