Electrical installation of THM20E
Electrical Installation
5.2
Electrical installation of THM20E
5.2.1
Equipotential bonding
You must establish local equipotential bonding between the individual mobile electrical
units to prevent excessive contact voltage in the event of a fault.
Install equipotential bonding as follows:
• Connect the THM20E pick-up and all additional units with the reference potential of
the mobile unit in line with high-frequency guidelines. Establish a wide-area, metallic
contact between the unit housing and the unpainted body of the mobile unit.
• Between the THM20E pick-up and the metallic mounting plate (vehicle support
frame), you must establish low-impedance equipotential bonding via a screw con-
nection with a toothed washer on one side at a retaining screw of the THM20E pick-
up.
WARNING
Faulty installation.
Severe or fatal injuries.
• It is essential to comply with the safety notes in chapter 2 during installation.