5
Single-point synchronization
Line cable connection
Product Manual – MOVITRANS
®
TES31A Decentralized Supply Unit Synchronization
37
Observe the following when connecting the protective earth:
1. Route the equipotential bonding cable [A] parallel to the supply cable [4].
2. Route the protective earths [B], [C] connected to the TVS and TCS parallel to the
load cables [6].
Prepare the connection distributor and connect the line cables
The following figure shows the TVS10A connection distributor:
[8]
[7]
[1]
[2]
[3]
[4]
[5]
[6]
31344529419
[1]
EMC screw fitting M25
[5]
EMC screw fitting M32
[2]
Screw plug made of metal
[6]
EMC screw fitting M32
[3]
EMC screw fitting M25
[7]
Terminal block in delivery state with
four jumper connections in each
case
[4]
EMC screw fitting M25
[8]
TVS10A connection distributor
Proceed as follows to connect the line cable:
1. To open the TVS10A connection distributor, loosen the four M5 hex head screws
on the housing cover.
2. First screw in the lower cable glands, and then the upper cable glands and the
screw plug in the following sequence: [4], [3], [1], [2].
3. Unscrew all the M6 connection screw fittings from the terminal studs.
4. Remove the 16 jumper connections.
29190657/EN – 04/2020