3
Flatpack resistors
Startup and operation
Manual – Accessories
15
4. Attach the braking resistor by inserting the supplied screws through the holes [C]
into the tapped holes on the side of the frequency inverter.
5. Position the fan insert back on the housing.
6. Connect the braking resistor to the terminals "+" or "DC+" and "BR" of the fre-
quency inverter. See the section "Installation of IP20" (→
10).
3.4
Startup and operation
For MOVITRAC
®
LTE-B+:
•
Set parameter
P-14
to "101" to gain access to the advanced menu.
•
Set parameter
P-34
to "1" to release the brake chopper.
For MOVITRAC
®
LTP-B:
•
Set parameter
P1-14
to "201" to gain access to the advanced menu.
•
Set parameter
P6-19
braking resistance value.
•
Set parameter
P6-20
braking resistor power.
23540052/EN – 06/2018