![SEW-Eurodrive MOVITRAC 07 Скачать руководство пользователя страница 88](http://html1.mh-extra.com/html/sew-eurodrive/movitrac-07/movitrac-07_system-manual_1250133088.webp)
5
88
System Manual – MOVITRAC® 07
Speed-torque characteristic
Project Planning
5.4
Speed-torque characteristic
5.5
Motor selection
Basic recommen-
dations
•
Only use motors with at least thermal classification F.
•
Use TF thermistor sensors.
•
Preferably use 4-pole motors. This applies particularly if you are operating geared
motors with a high oil filling level as a result of their vertical mounting position. The
churning losses are very great with 2-pole motors.
•
For operating conditions other than S1 operation: Operate the motor at its listed pow-
er without forced cooling.
03176BXX
Figure 42: Speed-torque characteristic
1. M at S3 25 % cdf
2. M at S1 100 % cdf
3. P at S1 100 % cdf
n [rpm]
2
1
n = 1400 rpm (50 Hz)
n
n = 1680 rpm (60 Hz)
n
P
P
N
M
M
N
1.6
1.4
1.2
1.0
0.8
0.6
0.4
0.2
0
0 100
300
600
1000
1400
» 50 Hz
1800
2200
2600
2900
» 100 Hz
M
max
3
n [rpm]
0 120
360
720
1200
1680
» 60 Hz
2160
2640
3120
3480
» 120 Hz