![SEW-Eurodrive MOVITRAC 07 Скачать руководство пользователя страница 65](http://html1.mh-extra.com/html/sew-eurodrive/movitrac-07/movitrac-07_system-manual_1250133065.webp)
System Manual – MOVITRAC® 07
65
4
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
Explanation of the parameters
Parameters
4
Parameters
As a rule, you only set the parameters during startup and if servicing is required. You
can set the MOVITRAC
®
07 parameters in various ways:
•
Using the integrated operating panel
•
Using the MOVITOOLS PC program on a PC connected via the RS-485 interface
•
Copying the parameters using the UBP11A parameter module
If you make any changes to the factory settings of the parameters: Enter the changes in
the Parameter list in the Startup section.
4.1
Explanation of the parameters
All parameters which can also be displayed and edited using the
symbol on the op-
erating panel have a
•
in the "OP" (operating panel) column. If more than one value can
be selected, the factory setting is highlighted in bold.
Par
No.
OP Name
Description
P
Motor startup parameters
If you are not connecting the motor indicated in the motor selection table: Enter parameters P-01 to P-05 correctly
according to the nameplate (access via
):
P-01
•
Operating mode
0 / VFC (field-oriented voltage flux control mode) or
VFC & HOIST (field-oriented control mode for hoist applications, can
only be set in MOVITOOLS)
3 / VFC & DC BRAK. (field-oriented control mode with DC braking)
4 / VFC &FLY.START (field-oriented control mode with flying restart circuit)
21 / V/f character. (voltage/frequency controlled mode)
22 / V/f & DC BRAKING (voltage/frequency controlled mode with DC brak-
ing)
P-02
•
Rated motor power
0.25, 0.37, 0.55 ... [kW]
Factory setting: Rated motor power in kW corresponding to the rated
inverter power
If a smaller or a larger motor is connected (maximum difference one frame
size), then a value must be selected which is as close as possible to the
rated motor power.
P-03
•
Rated motor speed
10 ... rated motor speed ... 5500 [rpm]
P-04
•
Rated motor frequency
50 [Hz] / 60 [Hz]
P-05
•
Rated motor voltage
50 ... 700 [V]