11
Service
Status LEDs
Manual – MOVISAFE
®
CSB51A Safety Option
39
11.2.1
"F-RUN” LED
The following table shows the states of the "F-RUN" LED.
LED status
Meaning
Flashing se-
quence
Device identification for memory module ID query.
Red, slowly
flashing
Device identification for parameterization.
Red, rapidly
flashing
Firmware update, do not switch the device off.
Green, rapidly
flashing
•
Device booting up/initializing
•
Device in parameterization state
Red
•
STO drive safety function is active
•
Critical fault (cannot be acknowledged)
Green, rapidly
flashing
•
Device in the operating state with one or more of the following
constraints:
– The safety card controls inverters
– Test mode
Green, slowly
flashing
Acceptance of the assembly has not yet taken place.
Off
Device off.
11.2.2
"F-ERR" LED
The following table shows the states of the "F-ERR" LED.
LED status
Priority
Meaning
Flashing se-
quence
-
Device identification for memory module ID query.
Red
1
Critical fault, cannot be acknowledged.
Yellow, rapidly
flashing
2
Encoder fault muting.
Red, slowly
flashing
3
•
Fault can be acknowledged
•
Fault outside of the device, cabling system fault
•
Reaction to limit value overshoot active
Yellow
4
Warning:
•
Error connection basic device
•
Firmware update, do not switch the device off.
Green, slowly
flashing
5
Error in the operating state "Parameterization":
•
Error in parameterization
•
No parameterization exists
•
Current parameter set not consistent with the
memory module
•
Inconsistent parameterization
Green
6
Fault-free operation.
25931075/EN – 04/2019