background image

7

Startup

Parameterization of the drive safety functions

Manual – MOVISAFE

®

 CSB51A Safety Option

23

7.3

Parameterization of the drive safety functions

7.3.1

Prerequisites

For  a  successful  startup,  you  need  the  "Assist  CS.."  parameterization  tool.  You  can
call up the "Assist CS.." parameterization tool directly in MOVISUITE

®

.

INFORMATION

Only one "Assist CS.." parameterization tool at a time must be used in the system.

7.3.2

Parameterization procedure

This chapter describes the parameterization of the drive safety functions step-by-step.

1. Start 

MOVISUITE

®

.

2.

Scan the network.

Scan the network that contains the engineering interface to the basic device.

3.

Start the "Assist CS.." parameterization tool.

Start the "Assist CS.." parameterization tool from the MOVISUITE

®

 interface.

A window opens with a prompt to enter the ID of the safety key and the password.

4.

Enter the memory module ID and establish a connection.

Enter the memory module ID of the safety option to be parameterized and the cor-
responding password and confirm the entry with [OK].

The memory module ID is printed on the memory module. During the initial startup
you can set a password by entering it twice.

The querying of the memory module ID ensures that the "Assist CS.." parameteri-
zation tool connects to the correct device.

As an alternative, you can read the memory module ID via the "Assist CS.." para-
meterization tool. Proceed as follows:

Click the [Read memory module ID] button.

Check  if  the  addressed  device  signals  a  read  memory  module  ID  via  the  "F-
RUN" LED (see chapter "F-RUN LED"). This process must only take a minute.
After one minute, the device LED does not flash anymore and confirmation of
the flash code is no longer accepted. In this case, restart the flash code query.

The read memory module ID is applied in the "Memory module ID" field.

5.

Upload the current parameterization of the device.

After  successful  login  in  the  "Assist  CS.."  parameterization  tool,  the  current  para-
meter setting of the CSB51A safety option is compared with the current parameter
setting in the "Assist CS..". If the data sets are identical, the "Assist CS.." parame-
terization  tool  starts.  In  case  of  deviation,  a  dialog  opens  in  which  the  user  can
choose whether the data set of the safety option or the data set of the "Assist CS.."
is used.

25931075/EN – 04/2019

Содержание MOVISAFE CSB51A

Страница 1: ...25931075_0419 Drive Technology Drive Automation System Integration Services Manual MOVI C Decentralized Electronics MOVISAFE CSB51A Safety Option Edition 04 2019 25931075 EN...

Страница 2: ...SEW EURODRIVE Driving the world...

Страница 3: ...ated use 10 2 5 Startup operation 11 2 6 Definitions 11 3 Safety concept 12 3 1 General information 12 3 2 Notes on stop categories 12 3 3 Memory module 12 3 4 Identification and authentication 13 3 5...

Страница 4: ...relevant acceptance 27 7 6 1 Sequence 27 7 6 2 Creating an acceptance report 28 7 6 3 Structure of the acceptance report 28 7 6 4 Confirming acceptance 28 7 7 Reset the password 29 7 7 1 Procedure 29...

Страница 5: ...afe connection 42 11 4 4 Fault memory 43 11 5 Emergency mode function 43 11 5 1 Safety notes 43 11 5 2 Approved devices 44 11 5 3 Prerequisites 44 11 5 4 Starting the emergency mode 44 11 5 5 Ending e...

Страница 6: ...safety notes 1 2 1 Meaning of signal words The following table shows the grading and meaning of the signal words for safety notes Signal word Meaning Consequences if disregarded DANGER Imminent hazard...

Страница 7: ...operation and fulfillment of any rights to claim under limited warranty Read the documentation before you start working with the product 1 4 Content of the documentation This documentation contains ad...

Страница 8: ...s reserved Unauthorized reproduction modifica tion distribution or any other use of the whole or any part of this documentation is strictly prohibited 1 8 Product names and trademarks The brands and p...

Страница 9: ...ns who work on the product pay attention to the following regula tions conditions documentation and information National and regional safety and accident prevention regulations Warning and safety sign...

Страница 10: ...ose of the instruction is that the persons are capable of performing the required tasks and work steps in a safe and correct manner 2 4 Designated use The product is integrated as an option in decentr...

Страница 11: ...the supply system and no longer carries any voltage In the event of deviations from normal operation switch the product off Possible devi ations are increased temperatures noise or vibration for examp...

Страница 12: ...2 Notes on stop categories The STO function corresponds to stop category 0 The SS1 c function corresponds to stop category 1 3 3 Memory module When switching on the basic device with the MOVISAFE CSB...

Страница 13: ...levant acceptance required for the system see chapter Startup requirements If the parameterization of the safety functions is changed the acceptance of the safety option must be confirmed The confirma...

Страница 14: ...STO function is activated the drive inverter no longer supplies power to the mo tor As a result the drive cannot generate torque This drive safety function corres ponds to a non controlled stop accor...

Страница 15: ...e according to EN 60204 1 stop category 1 t2 t1 t V t 9007201225618443 Drive safety function monitoring STO drive safety function active v Speed t Time t1 Point of time when SS1 c is activated and mot...

Страница 16: ...and the Assist CS parameterization tool are not safety related and therefore possibly not error free the safety concept prescribes the following measures Identification of MOVISAFE CSB51A When establi...

Страница 17: ...lication when a fault occurs the user must check whether the fault response time of each drive safety function is then shorter than the maximum permitted fault response time of the application The max...

Страница 18: ...The effectiveness of each risk minimization must be checked It must also be checked if the required safety integrity SIL and or PL is reached for each implemented safety function To validate the safet...

Страница 19: ...IDRIVE modular system technology with second en coder 5 Electronics cover of the basic device MOVI C decentralized electronics 1 Design characteristic A Technology version 5 2 Compatibility The follow...

Страница 20: ...general installation instructions and the notes in the operating instructions of the respective ba sic device that is used 6 2 Safe digital output F DO_STO The switching state of the internal output...

Страница 21: ...y option A system error is issued After acknowledging the system error the safety option is fully functional The safety option permanently activ ates the STO function 7 2 1 Variant 1 Startup with defa...

Страница 22: ...option can be parameterized and operated with the PROFIsafe protocol connection fieldbus connection Take into account the following constraints for this operating mode The parameters of the MOVISAFE C...

Страница 23: ...ry module ID is printed on the memory module During the initial startup you can set a password by entering it twice The querying of the memory module ID ensures that the Assist CS parameteri zation to...

Страница 24: ...e parameters of the drive safety functions STO and SS1 c are set The Assist CS parameterization tool creates a new parameter set from all of the parameters 7 Transferring the parameter set to the devi...

Страница 25: ...chanism For a successful startup you need the Assist CS parameterization tool Additional requirements for using the MOVISAFE CSB51A with PROFIsafe field bus connection via PROFIBUS or PROFINET TIA por...

Страница 26: ...tion 26 PROFIsafe master settings The settings that must be made at the PROFIsafe master are shown in an example for an S71500F in the TIA portal Transfer the F_iPar_CRC of the report to the PROFIsafe...

Страница 27: ...n occurs in the Safe state operating state The out put F DO_STO is disabled internally The Safe state operating state can be resolved only by deactivation and reactivation 7 6 Safety relevant acceptan...

Страница 28: ...specific data is transferred to the PDF file 7 6 3 Structure of the acceptance report The acceptance report that is generated as a PDF file contains the following informa tion System information Para...

Страница 29: ...equire the master password of the safety option 3 The master password of the option can be found on the inside of the electronics cover 4 Mount the electronics cover back onto the decentralized basic...

Страница 30: ...l preventive measures e g guard with guard locking device The additional preventive measures must cover the danger zone until no further danger to personnel exists The additional preventive measures m...

Страница 31: ...put data and 3 bytes output data The remaining 4 bytes input data and output data are required for the telegram backup according to the PROFIsafe specification 9 2 1 F periphery data component of the...

Страница 32: ...ser WARNING Disallowed parameterization of the variable ACK_NEC 0 Severe or fatal injuries The parameterization of the variable ACK_NEC 0 is permitted only if automatic reintegration is safe for the p...

Страница 33: ...serve 5 Reserve 6 Reserve 7 Fault ac knowledg ment 0 No acknowledgment 1 Fault acknowledgment 0 1 edge 1 0 Reserve 1 Reserve 2 Reserve 3 Reserve 4 Reserve 5 Reserve 6 Reserve 7 Reserve 2 0 Reserve 1 R...

Страница 34: ...l output F DO_STO is disabled 1 Reserve 2 Reserve 3 Reserve 4 Reserve 5 Reserve 6 Warning 0 CSB51A does not signal warning 1 CSB51A signals warning 7 Fault status 0 CSB51A is in fault free operation 1...

Страница 35: ...he value 0 is written for Fault state 9 5 Possible acknowledgment procedures of the safety option 9 5 1 Acknowledging fault free data exchange using PROFIsafe The PROFIsafe communication must be fault...

Страница 36: ...he safety docu mentation of the safety controller used For detailed information regarding response time consideration for safe PROFIsafe communication refer to the respective standard IEC 61784 3 3 10...

Страница 37: ...Calculation of response times Manual MOVISAFE CSB51A Safety Option 37 Calculation factor Calculation specification response time SS1 c Via F PA T_InputProcessing_F PA 2 T_Sys SSx c delay t1 8706 8 25...

Страница 38: ...fies the device internally e g ex change of components welding parts 11 2 Status LEDs WARNING Danger due to incorrect interpretation of the LEDs F RUN and F ERR Severe or fatal injuries The LEDs are n...

Страница 39: ...Test mode Green slowly flashing Acceptance of the assembly has not yet taken place Off Device off 11 2 2 F ERR LED The following table shows the states of the F ERR LED LED status Priority Meaning Fl...

Страница 40: ...er response Output fault Entry in fault memory and safe state of the F DO_STO if necessary System error Entry in fault memory and safe state of the F DO_STO Critical fault Entry in fault memory and sa...

Страница 41: ...ws the fault that occurred first in the safety op tion with the corresponding fault code subfault code and fault description For internal purposes additional fault codes are displayed The current firs...

Страница 42: ...C responds to the dispatched diagnostic alarm if the Diagnostic alarm as sembly parameter is enabled for the safety option in the F PLC per configuration De pending on the fieldbus used the fault code...

Страница 43: ...ault number the main fault text and the subfault text is displayed The actual value of the operating hours counter of the safety option is displayed in the Time column The Internal fault column is use...

Страница 44: ...e must be activated The Emergency mode function index 8702 2 must be enabled To start the emergency mode function a communication error must be pending in the F protocol 11 5 4 Starting the emergency...

Страница 45: ...llowing steps 1 Switch off the basic device to be replaced 2 Open the screw fitting of the electronics cover Remove the plugged in memory module from the electronics cover 3 Replace the electronics co...

Страница 46: ...rrent con sumption Maximum power consumption CSB51A 0 09 A 2 1 W 12 3 Characteristic safety values Characteristic values pursuant to EN 62061 IEC 61800 5 2 EN ISO 13849 1 Tested safety class underlyin...

Страница 47: ...error 40 Warning 40 F F process input data Substitute values 35 F process output data Substitute values 33 Fault classes Critical fault 41 Fault messages 41 Fault diagnostics Fault memory 43 Fault mes...

Страница 48: ...ments for stopping in an emergency ac cording to EN 60204 1 emergency stop 17 Startup requirements 17 Section related safety notes 6 Service 38 Device replacement 45 Fault diagnostics 41 Fault states...

Страница 49: ......

Страница 50: ......

Страница 51: ......

Страница 52: ...SEW EURODRIVE Driving the world SEW EURODRIVE GmbH Co KG Ernst Blickle Str 42 76646 BRUCHSAL GERMANY Tel 49 7251 75 0 Fax 49 7251 75 1970 sew sew eurodrive com www sew eurodrive com...

Отзывы: