![SEW-Eurodrive MOVIPRO SDC Скачать руководство пользователя страница 24](http://html.mh-extra.com/html/sew-eurodrive/movipro-sdc/movipro-sdc_manual_1250182024.webp)
24
Manual – MOVIPRO® SDC with DeviceNet Interface
4
Status and error messages
Installation Notes
Status LED S2
Status LED S3
LED status
Status or cause of error
Remedy
Flashing green
•
The firmware of the fieldbus gateway
is running properly.
–
Flashing green/
orange
•
Data backup is created/restored.
–
Lights up orange •
Boot process is active.
–
Flashing orange
•
Firmware is being updated.
–
Flashing red
•
No SD card plugged in.
•
File system of the SD card corrupt.
•
Boot process has failed.
•
Switch the unit off and back on again.
If the error occurs repeatedly, contact
the SEW Service staff.
LED status
Status or cause of error
Remedy
Lights up green
•
Gateway program is running.
–
Off
•
No gateway program is loaded.
•
Replace the SD card.