8
Operation
Status and error messages
Operating Instructions – MOVIPRO
®
PHE..B-A15-.1X0..B-00
76
8.4.2
Status LEDs
The device features additional LEDs for servicing. The status LEDS display additional
status information. The following table is used exclusively for diagnostics by the
SEW‑EURODRIVE Service.
[1]
[2]
[3]
[4]
[5]
[6]
[7]
[8]
[9]
[13]
[10]
[12]
[11]
[14]
[15]
[16]
11948037899
LED
LED status
Description
[1]
Positive half wave
command
Lights up red
The device receives positive half
waves from the command rail.
[2]
Phase failure
There is a phase failure.
[3]
Software status
Flashes red
The device software on the control
is operating.
[4]
24 V supply
Lights up green
There is an internal 24 V supply.
[5]
Supply service interface
The service interface is supplied.
[6]
Frequency inverter bus
supply
Lights up yellow
The frequency inverter bus is sup-
plied. This LED only lights up when
the operating switch is switched
on.
[7]
CPU supply
Lights up green
The CPU is supplied.
[8]
Negative half wave
command
Lights up red
The device receives negative half
waves from the command rail.
[9]
DIO00
The digital input 0 or the digital
output 0 is set.
[10]
DIO01
The digital input 1 or the digital
output 1 is set.
[11]
DI02
The digital input is set.
[12]
DI03
[13]
DI04
[14]
DI05
[15]
DI06
[16]
DI07
23576855/EN – 10/2017
Содержание MOVIPRO PHE Series
Страница 2: ...SEW EURODRIVE Driving the world...
Страница 97: ......
Страница 98: ......
Страница 99: ......